4.6 Article

Determination of endogenous brassinosteroids using sequential magnetic solid phase extraction followed by in situ derivatization/desorption method coupled with liquid chromatography-tandem mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1446, 期 -, 页码 103-113

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2016.04.012

关键词

Brassinosteriod; Sequential MSPE; In situ derivatization/desorption; LC-MS/MS

资金

  1. National Natural Science Foundation of China [91217309, 21475098]
  2. Natural Science Foundation of Hubei Province, China [2014CFA002]

向作者/读者索取更多资源

In this study, a sequential magnetic solid phase extraction followed by in situ derivatization/desorption method was proposed for the fast, selective and sensitive determination of brassinosteroids (BRs) in plant tissues. Magnetic sorbent for quick, easy, cheap, effective, rugged and safe method (mQuEChERS) and polymer(4-vinylphenylboronic acid-co-ethylene glycol dimethacrylate) coated Fe3O4@SiO2 (P(4-VPBA-co-EGDMA) coated Fe3O4@SiO2) were prepared and characterized. Using them as sorbents, pigments and hydrophilic interferents were firstly removed from plant extract by mQuEChERS, and then endogenous BRs were selectively enriched by p(4-VPBA-co-EGDMA) coated Fe3O4@SiO2 through boronate affinity interaction. After loading BRs on p(4-VPBA-co-EGDMA) coated Fe3O4@SiO2, instead of directly eluting free BRs, the adsorbed BRs were released by adding 4-(N,N-dimethyamino)phenylboronic acid (4-DMAPBA) solution for in situ derivatizaiton/desorption of BRs based on a transesterification reaction between the boronate moieties of p(4-VPBA-co-EGDMA) coated Fe3O4@SiO2 and 4-DMAPBA, finally the resultant solution was submitted to LC-MS/MS for quantification. The whole procedure of the sequential MSPE could be accomplished within 1 h, and the matrix effect to MS signal after the sample pretreatment was estimated to be in the range of 93.0-97.4%. The established method provided broad linear dynamics ranges (1.0-100.0 pg/mL) with correlation coefficients (R) >0.9978, substantial sensitivity (limits of detection ranged from 0.27 to 1.29 pg/mL), high reproducibility (intra-day and inter-day relative standard deviations (RSDs) less than 14.8%) and satisfactory accuracy (recoveries ranged from 74.0%-116.6%). Furthermore, endogenous BRs were successfully detected in one flower of Brassica napus L (22.5-542.7 pg/g fresh weight) and other plant tissues (13.7-289.8 pg/g fresh weight). (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据