This study retrieved ozone line parameters from high-resolution Fourier transform spectra and found systematic biases in atmospheric databases. The new intensity data with 1% accuracy will help resolve the UV-IR discrepancy in ozone studies.
Ozone line parameters have been retrieved from high-resolution Fourier transform spectra in the 5-mu m and 10-mu m spectral regions using a H-shaped cell with two parallel paths described in the first paper of the series (Multi-spectral investigation of ozone: Part I. Setup & uncertainty budget). The experimental arrangement allows for quasi simultaneous acquisition of spectra at 5 mu m and 10 mu m with consistent ozone pressure. A multispectrum fitting procedure has been used to accurately measure line positions and intensities. Special care has been taken to determine the instrument line shape and its effect on line intensities and sources of uncertainties from the assumption of a molecular line profile have been investigated. Line positions and intensities have been retrieved for 497 transitions at 10 mu m, mostly (476) from the nu(3) band, but also from the nu(1) band (18 transitions) and from the nu(2) + nu(3) - nu(2) hot band (3 transitions). At 5 mu m, 319 transitions have been determined, of which 316 belong to the nu(1)+nu(3) and 3 to the 2 nu(3) bands. Comparisons with previous experiments and calculations as well as with databases are presented, showing systematic discrepancies. The new intensity data at the unprecedented 1% accuracy level unambiguously indicates that atmospheric databases currently suffer from systematic biases up to 4.2% in the nu(1)+nu(3) band and 2.2% in the nu(3) band. The present results will help to resolve the long-standing UV-IR discrepancy observed in atmospheric and laboratory ozone studies. Comparisons with yet unpublished measurements and Hamiltonian-type calculations, as well as with recently published ab-initio calculations show an average discrepancy between 0.1% and 1.2% with sub-percent (0.4-0.8%) dispersion. The small scatter of the comparison confirms the sub-percent precision of both, the calculations, and the measurements. (C) 2021 Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据