4.7 Article

Microbial fuel cell (MFC)-based biosensor for combined heavy metals monitoring and associated bioelectrochemical process

期刊

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
卷 47, 期 49, 页码 21231-21240

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2022.04.225

关键词

Combined heavy metals; MFC biosensor; Charge transfer internal resistance; Bioelectrochemical process

资金

  1. National Natural Science Foundation of China [51808363, 51278318]
  2. Department of Science and Technology of Sichuan Province [2018SZ0302]
  3. Chengdu Science and Technology Bureau [2019-YF05-00839-SN]
  4. Dujiangyan Bureau of Eeconomy, Technology and Informationization [2020NY02]

向作者/读者索取更多资源

This study explores the feasibility and mechanism of MFC biosensor for wastewater detection under the action of combined heavy metals. The results indicate a linear relationship between the concentration and output voltage of the biosensor under the combined heavy metal group. However, the performance of the biosensor is mainly limited by Rct and needs further improvement.
To explore the feasibility and related mechanism of MFC biosensor for wastewater detection under the action of combined heavy metals. Cyclic voltammetry (CV) and scanning electrochemical impedance spectroscopy (EIS) were used to explore the related bioelectrochemical process. The response of the reactor to single/combined heavy metals, low/high heavy metal concentrations, and the differences in ohmic resistance (Rs) and charge transfer resistance (Rct) were investigated using Ni as the core heavy metal and the combined action of Cd, Cu and Zn. The results indicated that there was a linear relationship between the concentration and output voltage of the MFC biosensor under the action of combined heavy metals (R-2 = 0.8803-0.973). However, the internal resistance (Rint) of the MFC biosensor under the action of single heavy metal was far less than that of the combined heavy metal group, and the power density (19.849 W m(-3)) was 4 times that of the combined heavy metal group (3.109-4.589 W m(-3)). The Rs of the biosensors in the combined heavy metal group were 0.8681] and 0.860, which were higher than 0.7681] of the single heavy metal sensor. With the increase of the concentration of heavy metals in the influent, the increase of Rct was more obvious in the combined group, while the Rs in the single group significantly increased (P < 0.05). The results imply that it is possible for MFC biosensors to be used in the detection of actual water polluted by various heavy metals, but the biosensor performance is mainly limited by Rct, which needs to be further improved. (C) 2022 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据