4.7 Article

3D-printable aerogel-incorporated concrete: Anisotropy influence on physical, mechanical, and thermal insulation properties

期刊

CONSTRUCTION AND BUILDING MATERIALS
卷 323, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2022.126551

关键词

3D concrete printing; Thermal insulation; Aerogel-incorporated concrete; Anisotropy; Porosity

资金

  1. National Natural Science Foun-dation of China [42002190]
  2. Natural Science Foun-dation of Hebei [D2020202008, E2021202172]
  3. Postdoctoral Science Foundation of Hebei [B2020003023]
  4. China Postdoctoral Science Foundation [2020M670611]
  5. Open Fund of State Key Laboratory of Coal Resources and Safe Mining [SKLCRSM20KFA03]

向作者/读者索取更多资源

This study investigated the properties of fresh and hardened aerogel-incorporated concrete suitable for 3D concrete printing. The optimal replacement range for silica sand by aerogel in a cementitious mixture is found to be 0-20% by volume. The compressive strength of the cast specimens was slightly higher than those of the 3D printed specimens, and the thermal conductivity of the specimens decreased gradually with an increase in aerogel content.
This study investigated the properties of fresh and hardened aerogel (AG)-incorporated concrete suitable for 3D concrete printing. After trial and error, it was found, that to achieve the desired printability, the optimal replacement range for silica sand by aemgel in a cementitious mixture is 0-20% by volume. The physical, mechanical, and thermal insulation properties of hardened concrete in three directions were studied, and the influence of anisotropy on these properties was investigated. The results showed that irrespective of the aerogel content, the compressive strength of the cast specimens (avg. 24.90 MPa in A20) was slightly higher than those of the 3D printed specimens, 3DCP-X (avg. 23.63 MPa in A20), 3DCP-Y (avg. 20.77 MPa in A20), and 3DCP-Z (avg. 20.40 MPa in A20). The thermal conductivity of the cast and printed specimens decreased gradually with an increase in the aerogel content. Relative to that of the cast specimens (0.330 W/(m.K) in A20), the thermal conductivity of specimens 3DCP-X (0.405 W/(m.K) in A20) was slightly higher, while those of 3DCP-Y (0.320 W/ (m.K) in A20) and 3DCP-Z (0.306 W/(m.K) in A20) were lower. A thermal insulation wall (400 mm x 200 mm x 600 mm) with hollow structures was printed using the AG-incorporated concrete. To satisfy the same thermal and mechanical requirements, walls fabricated using AG-incorporated concrete can be 7 cm thinner than traditional concrete walls. The mechanism for the heat transfer of AG-incorporated concrete in three directions was examined as well.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据