4.7 Article

Experimental investigation on the compressive behaviour of FRP-confined rectangular concrete columns

期刊

出版社

SPRINGERNATURE
DOI: 10.1007/s43452-022-00450-4

关键词

Strengthening; Rectangular columns; Fibre-reinforced polymer (FRP); Confinement; Compression

资金

  1. CRUE-CSIC agreement
  2. Springer Nature

向作者/读者索取更多资源

This paper presents a comprehensive experimental study on the behaviour of FRP-confined concrete in square and rectangular columns and proposes improvements for the predictive models. The results show that FRP jacketing is an efficient technique for increasing the strength and strain capacity of columns, but its effectiveness decreases as the aspect ratio of the section increases. Significant strength improvement was achieved for low-strength concrete in rectangular sections with appropriate conditions.
This paper presents a comprehensive experimental study on the behaviour of FRP-confined concrete in square and rectangular columns and focuses on some issues that might be addressed with a view to improving the predictive models. For this purpose, 31 prismatic concrete specimens with a height of 600 mm and low- and medium-strength concrete (20-35 MPa) were tested under centred compression. The parameters studied were the aspect ratio between the sides of the section (1, 1.5 and 2), the radius of curvature of the corners (20, 25 and 30 mm) and the number of carbon FRP layers applied. The experimental results included stress-strain curves of specimens and detailed information about the confined concrete strength and the axial and lateral strain achieved on the FRP jacket during the tests. The stress-strain response and ultimate condition are analysed, showing that FRP jacketing is an efficient technique for increasing the strength and strain capacity, but that confinement efficiency decreases as the aspect ratio of the section increases. In spite of such decrease, significant strength improvement was achieved for low-strength concrete in rectangular sections with aspect ratios of 1.5 (strength gain up to 81%), and even 2 (up to 36%). The axial strength of the tests was compared with the design criteria of four international guidelines, resulting in predictions that did not properly fit for rectangular sections. A predictive equation is proposed to assess the axial compressive strength of the FRP-confined concrete, which includes a better adjustment for the strain efficiency factor and the shape factor for rectangular columns.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据