4.5 Article

One-year results following PASCAL-based or MitraClip-based mitral valve transcatheter edge-to-edge repair

期刊

ESC HEART FAILURE
卷 9, 期 2, 页码 853-865

出版社

WILEY PERIODICALS, INC
DOI: 10.1002/ehf2.13849

关键词

PASCAL; MitraClip; Mitral regurgitation; Transcatheter mitral valve edge-to-edge repair; TEER

资金

  1. Projekt DEAL

向作者/读者索取更多资源

Transcatheter edge-to-edge repair using the PASCAL or MitraClip device results in favorable and comparable outcomes regarding safety, efficacy, and clinical improvement after 1 year.
Aims Mitral valve transcatheter edge-to-edge repair (TEER) has been established as a suitable alternative to mitral valve surgery in patients with severe mitral regurgitation (MR) and high surgical risk. The PASCAL system represents a novel device, potentially augmenting the toolkit for TEER. The aim of this study was to assess and compare short and 1 year safety and efficacy of the PASCAL and MitraClip systems for TEER. Methods and results Procedural, short, and 1 year outcomes of a 1:2 propensity-matched cohort including 41 PASCAL and 82 MitraClip cases were investigated. Matching was based on clinical, laboratory, echocardiographic, and functional characteristics. The primary endpoints assessed were procedural success [as defined by the Mitral Valve Academy Research Consortium (MVARC)], residual MR, functional class, and a composite endpoint comprising death, heart failure hospitalization, and mitral valve re-intervention. We found for the PASCAL and the matched MitraClip cohort no significant differences in MVARC defined technical (90.2% vs. 95.1%, P = 0.44), device (90.2% vs. 89.0%, P = 1.0), or procedural (87.8% vs. 80.5%, P = 0.45) success rates. Accordingly, the overall MR reduction and improvement in New York Heart Association (NYHA) class were comparable (1 year follow-up: MR <= 2 95% vs. 93.6%, P = 1.0; NYHA <= 2 57.1% vs. 66.7%, P = 0.59). The composite outcome revealed no statistically significant difference between both devices (1 year follow-up: 31.7% vs. 37.8%, P = 0.55). Interestingly, we found at both short and 1 year follow-up a significantly higher rate of patients with none or trace MR in the PASCAL-treated cohort (short follow-up: 17.9% vs. 0%, P = 0.0081; 1 year follow-up: 25% vs. 0%, P = 0.0016). Conversely, the rate of aborted device implantations due to an elevated transmitral gradient was higher in PASCAL interventions (9.8% vs. 1.2%, P = 0.04). Conclusions Transcatheter edge-to-edge repair using the PASCAL or MitraClip device results in favourable and comparable outcomes regarding safety, efficacy, and clinical improvement after 1 year.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据