4.7 Article

Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fbioe.2021.799781

关键词

cadmium detection; negative feedback amplifier; sensitivity; specificity; whole-cell biosensor

资金

  1. National Key Research and Development Program of China [2018YFA0902100]
  2. National Natural Science Foundation of China [22178262, 21576197]

向作者/读者索取更多资源

A Cd2+ whole-cell biosensor with a negative feedback amplifier exhibited significantly improved sensitivity and specificity compared to traditional biosensors. This biosensor showed a lower detection limit and increased tolerance to Cd2+, making it suitable for real field applications. The negative feedback amplifier also provided faster response time and higher specificity for Cd2+ detection, showing its potential for enhancing biosensor performance.
Although many whole-cell biosensors (WCBs) for the detection of Cd2+ have been developed over the years, most lack sensitivity and specificity. In this paper, we developed a Cd2+ WCB with a negative feedback amplifier in P. putida KT2440. Based on the slope of the linear detection curve as a measure of sensitivity, WCB with negative feedback amplifier greatly increased the output signal of the reporter mCherry, resulting in 33% greater sensitivity than in an equivalent WCB without the negative feedback circuit. Moreover, WCB with negative feedback amplifier exhibited increased Cd2+ tolerance and a lower detection limit of 0.1 nM, a remarkable 400-fold improvement compared to the WCB without the negative feedback circuit, which is significantly below the World Health Organization standard of 27 nM (0.003 mg/L) for cadmium in drinking water. Due to the superior amplification of the output signal, WCB with negative feedback amplifier can provide a detectable signal in a much shorter time, and a fast response is highly preferable for real field applications. In addition, the WCB with negative feedback amplifier showed an unusually high specificity for Cd2+ compared to other metal ions, giving signals with other metals that were between 17.6 and 41.4 times weaker than with Cd2+. In summary, the negative feedback amplifier WCB designed in this work meets the requirements of Cd2+ detection with very high sensitivity and specificity, which also demonstrates that genetic negative feedback amplifiers are excellent tools for improving the performance of WCBs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据