4.7 Article

Acoustic-resolution photoacoustic microscope based on compact and low-cost delta configuration actuator

期刊

ULTRASONICS
卷 118, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.ultras.2021.106549

关键词

Photoacoustic imaging; Robotics; Acoustic-resolution photoacoustic microscopy; Delta configuration actuator; Beamforming

资金

  1. Worcester Polytechnic Institute internal fund
  2. Transformative Research and Innovation, Accelerating Discovery (TRIAD) grant
  3. National Institutes of Health [CA134675, EB024495, DP5 OD028162]

向作者/读者索取更多资源

The research introduced a low-cost sensor actuation device to reduce the size and cost of AR-PAM while maintaining image quality. Through simulation and experimental evaluation, the low-cost delta configuration actuators demonstrated applicability for AR-PAMs, with advanced reconstruction algorithms compensating for actuator motion errors.
The state-of-the-art configurations for acoustic-resolution photoacoustic (PA) microscope (AR-PAM) are large in size and expensive, hindering their democratization. While previous research on AR-PAMs introduced a low-cost light source to reduce the cost, few studies have investigated the possibility of optimizing the sensor actuation, particularly for the AR-PAM. Additionally, there is an unmet need to evaluate the image quality deterioration associated with the actuation inaccuracy. A low-cost actuation device is introduced to reduce the system size and cost of the AR-PAM while maintaining the image quality by implementing the advanced beamformers. This work proposes an AR-RAM incorporating the delta configuration actuator adaptable from a low-cost off-the-shelf 3D printer as the sensor actuation device. The image degradation due to the data acquisition positioning inaccuracy is evaluated in the simulation. We further assess the mitigation of potential actuation precision uncertainty through advanced 3D synthetic aperture focusing algorithms represented by the Delay-and-Sum (DAS) with Coherence Factor (DAS+CF) and Delay-Multiply-and-Sum (DMAS) algorithms. The simulation study demonstrated the tolerance of image quality on actuation inaccuracy and the effect of compensating the actuator motion precision error through advanced reconstruction algorithms. With those algorithms, the image quality degradation was suppressed to within 25% with the presence of 0.2 mm motion inaccuracy. The experimental evaluation using phantoms and an ex-vivo sample presented the applicability of low-cost delta configuration actuators for AR-PAMs. The measured full width at half maximum of the 0.2 mm diameter pencil-lead phantom were 0.45 +/- 0.06 mm, 0.31 +/- 0.04 mm, and 0.35 +/- 0.07 mm, by applying the DAS, DAS+CF, and DMAS algorithms, respectively. AR-PAMs with a compact and low-cost delta configuration provide high-quality PA imaging with better accessibility for biomedical applications. The research evaluated the image degradation contributed by the actuation inaccuracy and suggested that the advanced beamformers are capable of suppressing the actuation inaccuracy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。