POCT with advantages of simplicity, rapidity, portability, and low-cost is crucial for improving healthcare, while quantitative POCT of multiplexed biomarkers poses a challenge. A smartphone optical device has been designed for accurate testing of glucose and cholesterol using a ratiometric fluorescent sensor, showing great potential for portable detection of numerous targets in personalized healthcare and clinical diagnosis.
Point-of-care testing (POCT) with the advantages of simplicity, rapidity, portability, and low-cost is of great importance to improve healthcare, especially in resource-limited settings and home healthcare settings. Moreover, it is a great challenge to quantitative POCT of multiplexed biomarkers within a single accessible assay but provides enhanced diagnostic accuracy and improved diagnostic efficiency. Herein, a smartphone optical device has been designed for POCT of glucose and cholesterol in metabolic syndrome patients using a ratiometric fluorescent sensor. The sensing system of Ag NPs/UiO-66-NH2 and o-phenylenediamine presents a dual-emission response to H2O2 (the main product of glucose and cholesterol catalyzed by glucose oxidase and cholesterol oxidase) on account of the inner filter effect, resulting in an increase in the response of the fluorescence intensity ratio (F-555 (nm)/F-425 (nm)) accompanied by a distinguishable color transition from blue to yellow green. After compositing probes with a flexible substrate, the obtained test strip can be integrated with a smartphone-based portable platform to read RGB values for accurate testing of glucose and cholesterol with both detection limits of 10 mu mol L-1, which are hundreds of times lower than their concentrations in human serum. With the advantages of low-cost, ease of operation, and broad adaptability, this smartphone optical device holds great potential for portable detection of numerous targets in personalized healthcare and clinical diagnosis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据