4.8 Article

Three-Dimensional Printed Dual-Mode Chemical Vapor Generation Point Discharge Optical Emission Spectrometer for Field Speciation Analyses of Mercury and Inorganic Selenium

期刊

ANALYTICAL CHEMISTRY
卷 93, 期 45, 页码 14923-14928

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.1c02023

关键词

-

资金

  1. National Nature Science Foundation of China [22076128, 21622508]
  2. Excellent Youth Foundation of Sichuan Scientific Committee [2019JDJQ0024]

向作者/读者索取更多资源

This study developed a portable and compact system device for field speciation analyses of mercury and inorganic selenium using 3D printing technology. The device showed improved accuracy and practicality in analysis, highlighting the potential of 3D printing for creating simple and efficient atomic spectrometers for field elemental speciation analysis.
Due to the large size and high energy consumption of instruments, field elemental speciation analysis is still challenging so far. In this work, a portable and compact system device (230 mm length x 38 mm width x 84 mm height) was fabricated by using three-dimensional (3D) printing technology for the field speciation analyses of mercury and inorganic selenium. The device comprises a cold vapor generator, photochemical vapor generator, and miniaturized point discharge optical emission spectrometer (mu PD-OES). For mercury, inorganic mercury (IHg) was selectively reduced to Hg-0 by cold vapor generation, whereas the reductions of both IHg and methylmercury (MeHg) were obtained by photochemical vapor generation (PVG) in the presence of formic acid. For selenium, Se(IV) and total inorganic selenium were converted to their volatile species by PVG in the presence and the absence of nano-TiO2, respectively. The generated volatile species were consequently detected by mu PD-OES. Limits of detection of MeHg, IHg, Se(IV), and Se(VI) were 0.1, 0.1, 5.2, and 3.5 mu g L-1, respectively. Precision expressed as the relative standard deviations (n = 11) were better than 4.5%. The accuracy and practicality of the proposed method were evaluated by the analyses of Certified Reference Materials (DORM-4, DOLT-5, and GBW(E)080395) and several environmental water samples with satisfactory recoveries (95-103%). This work confirms that 3D printing has great potential to fabricate a simple, miniaturized, easy-to-operate, and low gas and power consuming atomic spectrometer for field elemental speciation analysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据