4.7 Article

Anchoring luminol based on Ti3C2-mediated in situ formation of Au NPs for construction of an efficient probe for miRNA electrogenerated chemiluminescence detection

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 413, 期 28, 页码 6963-6971

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-021-03651-7

关键词

Ti(2)C(3)Tx MXene; Ti vacancy defects; Luminol anchoring; Electrogenerated chemiluminescence; Probe; Signal amplification

资金

  1. Taishan Scholar Program of Shandong Province [ts201511027]
  2. Natural Science Foundation of Shandong Province [ZR2020MB063]

向作者/读者索取更多资源

An efficient ECL nanoprobe was constructed based on Ti3C2-mediated in situ formation of Au NPs and anchoring luminol to fabricate a sensitive ECL biosensor for miRNA-155 detection. The probe exhibited a linear range from 0.3 fM to 1 nM with a detection limit of 0.15 fM, demonstrating high reliability of miRNA-155 detection even in human serum samples. This work opens a new chapter for the application of Ti3C2 in the field of bioanalysis with excellent ECL emission.
An efficient electrogenerated chemiluminescence (ECL) nanoprobe (luminol-Au NPs-Ti3C2) was constructed based on Ti(3)C(2)Tx MXene (Ti3C2)-mediated in situ formation of Au NPs and anchoring luminol to fabricate a sensitive ECL biosensor for miRNA-155 detection. Herein, Ti3C2 with rich Ti vacancy defects was used as reducing agent, and Au NPs were generated in situ and anchored on the Ti3C2 (Au NPs-Ti3C2). Moreover, the Au NPs-Ti3C2 composites were used as a carrier and provided a large number of sites for the efficient linking of luminol through Au-N bonds to form stable luminol-Au NPs-Ti3C2. The immobilization of ECL emitters is a versatile strategy which not only shortens the electron transmission distance between luminol and electrode, but also provides naked catalytic predominated (111) facets of Au NPs with high electrocatalytic activity, significantly improving the ECL signal of luminol. Furthermore, a catalytic hairpin assembly (CHA) reaction was used, resulting in further amplification of the signal. As a result, the as-prepared ECL biosensor exhibited a linear range from 0.3 fM to 1 nM with a detection limit of 0.15 fM, and demonstrated high reliability of miRNA-155 detection even in human serum samples. The construction of a multifunctional ECL probe with excellent ECL emission opens a new chapter for the application of Ti3C2 in the field of bioanalysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据