4.6 Article

Heat Transfer Coefficient Estimation and Performance Evaluation of Shell and Tube Heat Exchanger Using Flue Gas

期刊

PROCESSES
卷 9, 期 6, 页码 -

出版社

MDPI
DOI: 10.3390/pr9060939

关键词

shell tube heat exchanger; poultry litter; natural gas co-combustion; flue gas; specific heat; overall heat transfer coefficient; effectiveness

资金

  1. Maryland Industrial Partnerships (MIPS)
  2. Office of Technology Transfer (OTT) at Morgan State University
  3. Maryland Department of Natural Resources (DNR)

向作者/读者索取更多资源

This study aimed to evaluate the performance of a pilot-scale twisted tube-based heat exchanger using flue gas from biomass co-combustion as the working fluid. A simplified model was developed by integrating two heat transfer methods to predict the overall heat transfer coefficient.
In the past few decades, water and air were commonly used as working fluid to evaluate shell and tube heat exchanger (STHE) performance. This study was undertaken to estimate heat transfer coefficients and evaluate performance in the pilot-scale twisted tube-based STHE using the flue gas from biomass co-combustion as working fluid. Theoretical calculation along with experimental results were used to calculate the specific heat of flue gas. A simplified model was then developed from the integration of two heat transfer methods to predict the overall heat transfer coefficient without tedious calculation of individual heat transfer coefficients and fouling factors. Performance including water and trailer temperature, heat load, effectiveness, and overall heat transfer coefficient were jointly investigated under variable operating conditions. Results indicated that the specific heat of flue gas from co-combustion ranging between 1.044 and 1.338 kJ/kg center dot K while specific heat was increased by increasing flue gas temperature and decreasing excess air ratio. The developed mathematical model was validated to have relatively small errors to predict the overall heat transfer coefficient. A flue gas mass flow rate of 61.3-98.8 kg/h, a water flow rate of 13.7-14.1 L/min, and a parallel arrangement of two water-to-air heaters in an empty trailer were found to be optimal conditions for space heating purpose. In addition, a lower poultry litter feeding rate decreased heat loss of flue gas and increased heat gain of water, while a lower water flow rate also provided a lower maximum possible heat transfer rate with a higher actual heat transfer rate to quickly achieve heat equilibrium that ultimately improves the performance. This study demonstrates the possibility of collecting residual heat from the flue gas using the pilot-scale STHE system while outlining a systematic approach and process for evaluating its performance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据