4.7 Article

Comparative diagnostic performance of volumetric laser endomicroscopy and confocal laser endomicroscopy in the detection of dysplasia associated with Barrett's esophagus

期刊

GASTROINTESTINAL ENDOSCOPY
卷 83, 期 5, 页码 880-U58

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.gie.2015.08.050

关键词

-

资金

  1. National Cancer Center [U01 CA182940, U54 CA163004, P30 CA015083]
  2. National Institute of Health [UL1TR000135]

向作者/读者索取更多资源

Background and Aims: Probe-based confocal laser endomicroscopy (pCLE) and volumetric laser endomicroscopy (VLE) (also known as frequency domain optical coherence tomography) are advanced endoscopic imaging modalities that may be useful in the diagnosis of dysplasia associated with Barrett's esophagus (BE). We performed pCLE examination in ex-vivo EMR specimens and compared the diagnostic performance of using the current VLE scoring index (previously established as OCT-SI) and a novel VLE diagnostic algorithm (VLE-DA) for the detection of dysplasia. Methods: A total of 27 patients with BE enrolled in a surveillance program at a tertiary-care center underwent 50 clinically indicated EMRs that were imaged with VLE and pCLE and classified into neoplastic (N = 34; high-grade dysplasia, intramucosal adenocarcinoma) and nonneoplastic (N = 16; low-grade dysplasia, nondysplastic BE), based on histology. Image datasets (VLE, N = 50; pCLE, N = 50) were rated by 3 gastroenterologists trained in the established diagnostic criteria for each imaging modality as well as a new diagnostic algorithm for VLE derived from a training set that demonstrated association of specific VLE features with neoplasia. Sensitivity, specificity, and diagnostic accuracy were assessed for each imaging modality and diagnostic criteria. Results: The sensitivity, specificity, and diagnostic accuracy of pCLE for detection of BE dysplasia was 76% (95% confidence interval [CI], 59-88), 79% (95% CI, 53-92), and 77% (95% CI, 72-82), respectively. The optimal diagnostic performance of OCT-SI showed a sensitivity of 70% (95% CI, 52-84), specificity of 60% (95% CI, 36-79), and diagnostic accuracy of 67%; (95% CI, 58-78). The use of the novel VLE-DA showed a sensitivity of 86% (95% CI, 69-96), specificity of 88% (95% CI, 60-99), and diagnostic accuracy of 87% (95% CI, 86-88). The diagnostic accuracy of using the new VLE-DA criteria was significantly superior to the current OCT-SI (P <.01). Conclusion: The use of a new VLE-DA showed enhanced diagnostic performance for detecting BE dysplasia ex vivo compared with the current OCT-SI. Further validation of this algorithm in vivo is warranted.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据