期刊
FORENSIC SCIENCE INTERNATIONAL
卷 325, 期 -, 页码 -出版社
ELSEVIER IRELAND LTD
DOI: 10.1016/j.forsciint.2021.110888
关键词
Cathinone derivatives; Detection and quantification analyses; Liquid chromatography-electrospray ionization linear ion trap mass spectrometry (LC-ESI-LIT-MS); Gas chromatography-electron ionization mass spectrometry (GC-EI-MS)
资金
- Japan Society for the Promotion of Sciences (JSPS) [17H00737]
This case study presents a fatal poisoning involving several cathinones, detected and quantified using LC-ESI-LIT-MS in authentic human whole blood samples. The LC-ESI-LIT-MS method showed high specificity for qualitative analysis of cathinones compared to GC-EI-MS. Validation data revealed good linearity and reproducibility for quantitative analysis of the compounds.
We present a case of fatal poisoning by 4-F-methcathinone (4-FMC; also called flephedrone), 4-methoxy-alpha-pyrrolidinopentiophenone (4-MeO-alpha-PVP), 4-fluoro-alpha-pyrrolidinopentiophenone (4-F-alpha-PVP), and alpha-pyr-rolidinohepatanophenone (PV8). In this study, we compared the mass spectra of 4-FMC, 4-MeO-alpha-PVP, 4-F-alpha-PVP, PV8, and alpha-pyrrolidinohexanophenone between LC-ESI-LIT-MS and GC-EI-MS analyses. Subsequently, we applied LC-ESI-LIT-MS for detection and quantification analyses of 4-FMC, 4-MeO-alpha-PVP, 4-F-alpha-PVP, and PV8 in human authentic whole blood samples. More specific mass spectra for the target compounds were obtained with the LC-ESI-LIT-MS qualitative analyses than with the GC-EI-MS analyses, indicating that LC-ESI-LIT-MS was more suitable for the qualitative analysis of cathinones. The LC-ESI-LIT-MS validation data showed moderately good linearity and reproducibility for the compounds in the quantitative analyses at the range of 1-500 ng/mL. The detection limits of four cathinones ranged from 0.1 to 1 ng/mL. The concentrations of 4-FMC, 4-MeO-alpha-PVP, 4-F-alpha-PVP, and PV8 in heart whole blood samples were 365, 449, 145, and 218 ng/mL, respectively. Those of the 4 cathinones in femoral vein whole blood samples were 397, 383, 127, and 167 ng/mL, respectively. We can then assume that the cause of death was acute poisoning by a combination of 4-FMC, 4-MeO-alpha-PVP, 4-F-alpha-PVP, and PV8. In this article, we present a detailed LC-ESI-LIT-MS procedure for detection and quantification analyses of 4-FMC, 4-MeO-alpha-PVP, 4-F-alpha-PVP, and PV8 in authentic human whole blood samples. (c) 2021 The Author(s). Published by Elsevier B.V. CC_BY_NC_ND_4.0
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据