期刊
EXPERIMENTAL THERMAL AND FLUID SCIENCE
卷 70, 期 -, 页码 105-114出版社
ELSEVIER SCIENCE INC
DOI: 10.1016/j.expthermflusci.2015.08.012
关键词
Jet cooling; Ultrafast cooling; Run out table; Heat flux; Cooling rate; Polyvinylpyrrolidone
The current research focuses on the enhancement of heat transfer of a hot steel plate by introducing polymer additive, polyvinylpyrrolidone (PVP) in jet cooling. The characterization of PVP solution has been done in order to understand the reason for increment in heat transfer. The concentration of PVP has been varied at levels ranging from 50 to 150 ppm along with the variation of flow rate from 13.3 x 10(-5) to 33.33 x 10(-5) m(3)/s (8 to 201pm). The results indicate that the addition of PVP in water jet leads to an appreciable increase in cooling rate and surface heat flux compared to that of water which leads to lesser coolant consumption. A PVP concentration of 110 ppm in water is found to provide a maximum cooling rate of 231 degrees C/s and a maximum critical heat flux of 3.01 MW/m(2) which are higher than that of water by 111.18% and 19% respectively. (C) 2015 Elsevier Inc. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐