4.8 Article

A capillary driven microfluidic chip for SERS based hCG detection

期刊

BIOSENSORS & BIOELECTRONICS
卷 195, 期 -, 页码 -

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2021.113660

关键词

Human chorionic gonadotropin protein; Metal organic framework; Capillary driven microfluidic chip; Surface enhanced Raman spectroscopy

资金

  1. Gazi University Scientific Research Department (Ankara, Turkey) [02/2019-16]

向作者/读者索取更多资源

This study developed a capillary driven microfluidic chip-based immunoassay for the determination of prohibited hCG protein. The method showed high selectivity and accuracy in detecting various proteins, with a regression coefficient of 0.9985 and a limit of detection of 0.61 IU/L. The analysis system developed for target proteins could serve as an alternative to traditional methods such as Western Blot, offering a more cost-effective and time-saving solution.
In this study, a capillary driven microfluidic chip-based immunoassay was developed for the determination of Human Chorionic Gonadotropin (hCG) protein, which is prohibited by the World Anti-Doping Agency (WADA). Here, we used antibody modified magnetic metal organic framework nanoparticles (MMOFs) as a capture prob in urine sample. MMOF captured hCG was transferred in a capillary driven microfluidic chip consisting of four chambers, and the interaction of MMOF with gold nanorods labelled with 5,5'-Dithiobis-(2-nitrobenzoic acid) (DTNB) as a Raman label was carried out in the capillary driven microfluidic chip. The movement of MMOF through first chamber to the last chamber was achieved with a simple magnet. In the last chamber of capillary driven microfluidic chip, SERS signals of DTNB molecules from the sandwich complex were recorded using a Raman spectrophotometer. The selectivity of the developed method was demonstrated by applying the same procedure for the detection of Human Luteinizing Hormone (hLH), Human Chorionic Gonadotropin Hormone (hGH) and Immunoglobulin G (IgG) protein. The regression coefficient and limit of detection obtained from the standard addition method were found as 0,9985 and 0,61 IU/L, respectively. Furthermore, the conventional ELISA method confirmed that the results obtained by the presented method were acceptable with the similarity of 97.9% in terms of average recovery value, for the detection of hCG in urine samples. The analysis system developed for target proteins will be an alternative technique such as Western Blot used in routine analysis that is expensive and time consuming.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据