4.5 Article

A quantitative evaluation of aerosol generation during supraglottic airway insertion and removal

期刊

ANAESTHESIA
卷 76, 期 12, 页码 1577-1584

出版社

WILEY
DOI: 10.1111/anae.15542

关键词

aerosol-generating procedure; COVID-19; SARS-CoV-2; supraglottic airway device

资金

  1. National Institute for Health Research (NIHR) [NIHR301520]
  2. Natural Environment Research Council [NE/P018459/1]
  3. Wellcome GW4
  4. NIHR-UKRI rapid rolling grant
  5. NERC [NE/P018459/1] Funding Source: UKRI
  6. National Institutes of Health Research (NIHR) [NIHR301520] Funding Source: National Institutes of Health Research (NIHR)

向作者/读者索取更多资源

The study found that the use of supraglottic airways generates minimal bio-aerosols compared to breathing and significantly less than a cough. This information should be taken into consideration when designing infection prevention strategies for healthcare workers caring for patients with supraglottic airways.
Many guidelines consider supraglottic airway use to be an aerosol-generating procedure. This status requires increased levels of personal protective equipment, fallow time between cases and results in reduced operating theatre efficiency. Aerosol generation has never been quantitated during supraglottic airway use. To address this evidence gap, we conducted real-time aerosol monitoring (0.3-10-mu m diameter) in ultraclean operating theatres during supraglottic airway insertion and removal. This showed very low background particle concentrations (median (IQR [range]) 1.6 (0-3.1 [0-4.0]) particles.l(-1)) against which the patient's tidal breathing produced a higher concentration of aerosol (4.0 (1.3-11.0 [0-44]) particles.l(-1), p = 0.048). The average aerosol concentration detected during supraglottic airway insertion (1.3 (1.0-4.2 [0-6.2]) particles.l(-1), n = 11), and removal (2.1 (0-17.5 [0-26.2]) particles.l(-1), n = 12) was no different to tidal breathing (p = 0.31 and p = 0.84, respectively). Comparison of supraglottic airway insertion and removal with a volitional cough (104 (66-169 [33-326]), n = 27), demonstrated that supraglottic airway insertion/removal sequences produced <4% of the aerosol compared with a single cough (p < 0.001). A transient aerosol increase was recorded during one complicated supraglottic airway insertion (which initially failed to provide a patent airway). Detailed analysis of this event showed an atypical particle size distribution and we subsequently identified multiple sources of non-respiratory aerosols that may be produced during airway management and can be considered as artefacts. These findings demonstrate supraglottic airway insertion/removal generates no more bio-aerosol than breathing and far less than a cough. This should inform the design of infection prevention strategies for anaesthetists and operating theatre staff caring for patients managed with supraglottic airways.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据