4.7 Article

Rapid, sensitive and label-free detection of pathogenic bacteria using a bacteria-imprinted conducting polymer film-based electrochemical sensor

期刊

TALANTA
卷 226, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.talanta.2021.122135

关键词

Molecularly imprinted polymer; Electrochemical sensor; Label-free; Bacteria imprinting; Conductive polymer; Thiophene

资金

  1. National Natural Science Foundation of China [21405167, 21775102]
  2. Shanghai Chenguang Program [15CG54]
  3. Shanghai Young Origental Schloars Program [QD2017037]

向作者/读者索取更多资源

A bacteria-imprinted conductive poly(3-thiopheneacetic acid) (BICP) film-based impedimetric sensor was developed for rapid, sensitive, and label-free detection of staphylococcus aureus. The sensor showed extremely rapid recognition, very low limit of detection, wide linear range, high selectivity, and good universality and repeatability, with feasibility demonstrated in the analysis of real milk samples. This sensor offers a simple and universal method for the detection of pathogenic bacteria, holding great potentials in food safety applications.
The rapid and sensitive detection of pathogenic bacteria is very important for timely prevention and treatment of foodborne disease. Here, a bacteria-imprinted conductive poly(3-thiopheneacetic acid) (BICP) film-based impedimetric sensor was developed for the rapid, sensitive and label-free detection of staphylococcus aureus (S. aureus). The BICP film preparation was very convenient and eco-friendly, which was in situ deposited on gold electrode surface without the use of toxic organic solvents and cross-linkers. The process of imprinting and recognition were characterized by electrochemical technique and scanning electron microscope. The BICP had a novel structure without cocci-shaped cavities formed in the poly(3-thiopheneacetic acid) (PTAA) matrices. To obtain the optimal sensing performance, a set of factors affecting the imprinting and recognition were investigated. Under the optimized conditions, an extremely rapid recognition within 10 min, a very low limit of detection (LOD) of 2 CFU/mL, and wide linear range from 10 to 10(8) CFU/mL were achieved by the BICP film-based impedimetric sensor. The sensor also demonstrated high selectivity, and good universality and repeatability. Furthermore, the feasibility of its application has also been demonstrated in the analysis of real milk samples. This sensor offered a simple and universal method for rapid, sensitive, and selective detection of pathogenic bacteria, which could hold great potentials in fields like food safety.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据