4.7 Article

Seismic performance of optimal Multi-Tuned Liquid Column Damper-Inerter (MTLCDI) applied to adjacent high-rise buildings

期刊

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.soildyn.2021.106653

关键词

Multi-tuned liquid column damper-inerter; Adjacent high-rise buildings; Seismic design; Parametric optimization

资金

  1. Key Laboratory of Structure and Wind Tunnel of Guangdong Higher Education Institutes

向作者/读者索取更多资源

A novel passive vibration control system, Multi-Tuned Liquid Column Damper-Inerter (MTLCDI), is developed to control the seismic response of adjacent high-rise buildings. The study shows that in most cases, IS-MTLCDI outperforms IB-MTLCDI in reducing earthquake-induced vibrations.
Conventional vibration absorbers, e.g., a classical tuned mass damper, may be not efficient in simultaneously controlling the seismic response of adjacent high-rise buildings. In this paper, a novel passive vibration control system, denoted as Multi-Tuned Liquid Column Damper-Inerter (MTLCDI), is developed to control the seismic response of adjacent high-rise buildings. Two different configurations of this system, namely inter-story MTLCDI (IS-MTLCDI) and inter-building MTLCDI (IB-MTLCDI), are proposed, and related mathematical models are developed to investigate the seismic performance of MTLCDI. A case study project comprising two adjacent highrise buildings equipped with the proposed system and subjected to ten earthquake records with various frequency characteristics is considered. Performance-based parametric optimization of the MTLCDI systems is performed through two distinct constrained multi-objective optimization problems via genetic algorithms, wherein peak absolute accelerations and inter-story drift ratios of the two adjacent buildings are selected as performance indexes. The mitigation effects of optimum IS-MTLCDI and IB-MTLCDI on earthquake-induced vibrations are scrutinized, with emphasis placed on the effects of natural frequency ratios between the two host structures. The results indicate that, when the two buildings have distinct natural frequencies, both ISMTLCDI and IB-MTLCDI outperform inter-building single TLCDI as well as other vibration absorbers in terms of seismic vibration control of absolute acceleration and inter-story drift ratios. Under most natural frequency ratios, the IS-MTLCDI achieves a larger response reduction than IB-MTLCDI. Nevertheless, when the differences between natural frequencies of adjacent buildings are significant, applying an IB-MTLCDI may be preferable due to its satisfactory mitigation effects combined with ease of installation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据