4.5 Article

Comparison of droplet spread in standard and laminar flow operating theatres: SPRAY study group

期刊

JOURNAL OF HOSPITAL INFECTION
卷 110, 期 -, 页码 194-200

出版社

W B SAUNDERS CO LTD
DOI: 10.1016/j.jhin.2021.01.026

关键词

Fluorescein; COVID-19; Aerosol-generating procedure (AGP); Operating theatre; Droplets; Image analysis

资金

  1. Impact Accelerator Account, Science and Technology Facilities Council
  2. Royal Society Wolfson Fellowship
  3. Natural Environment Research Council [NE/P018459/1]
  4. MRC [MR/K002597/1] Funding Source: UKRI
  5. NERC [NE/P018459/1] Funding Source: UKRI
  6. STFC [ST/S002731/1] Funding Source: UKRI

向作者/读者索取更多资源

Accurate mapping of droplet spread in clinical environments is possible using fluorescein staining and image analysis. Laminar air flow mainly affected smaller droplets, with limited impact on larger droplets.
Background: Reducing COVID-19 transmission relies on controlling droplet and aerosol spread. Fluorescein staining reveals microscopic droplets. Aim: To compare the droplet spread in non-laminar and laminar air flow operating theatres. Methods: A 'cough-generator' was fixed to a theatre trolley at 45 degrees. Fluorescein-stained 'secretions' were projected on to a series of calibrated targets. These were photographed under UV light and 'source detection' software measured droplet splatter size and distance. Findings: The smallest droplet detected was similar to 120 mm and the largest similar to 24,000 mm. An average of 25,862 spots was detected in the non-laminar theatre, comparedwith 11,430 in the laminar theatre (56% reduction). The laminar air flow mainly affected the smaller droplets (<1000 mm). The surface area covered with droplets was: 6% at 50 cm, 1% at 2 m, and 0.5% at 3 m in the non-laminar air flow; and 3%, 0.5%, and 0.2% in the laminar air flow, respectively. Conclusion: Accurate mapping of droplet spread in clinical environments is possible using fluorescein staining and image analysis. The laminar air flow affected the smaller droplets but had limited effect on larger droplets in our 'aerosol-generating procedure' cough model. Our results indicate that the laminar air flow theatre requires similar post-surgery cleaning to the non-laminar, and staff should consider full personal protective equipment for medium- and high-risk patients. (C) 2021 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据