Thirty-Day Results of the Novel CGuard-Covered Stent in Patients Undergoing Carotid Artery Stenting

期刊

JOURNAL OF ENDOVASCULAR THERAPY
卷 28, 期 4, 页码 542-548

出版社

SAGE PUBLICATIONS INC
DOI: 10.1177/15266028211007466

关键词

carotid artery stenting; carotid artery stenosis; double mesh technology; mesh-covered stent; stroke

向作者/读者索取更多资源

The study demonstrates that the CGuard stent with EPS is an effective and safe device for treating carotid artery stenosis, with acceptable low perioperative neurological event rates even with low usage of embolic protection devices.
Objective: The aim of this study was to provide early-term evaluation, safety, and efficacy of the novel CGuard (Inspire MD, Tel Aviv, Israel) micromesh self-expanding stent with embolic protection system (EPS) during carotid artery stenting (CAS) procedure. Materials and Methods: All patients who underwent CAS with CGuard carotid stent system from January 2018 to September 2020 in a tertiary center were prospectively evaluated. Primary endpoints included technical success and perioperative neurological events (0-48 hours). Secondary endpoint was the rate of neurologic, cardiac events, and death (major adverse event or MAE) at 30 days. Patency of CGuard, peak systolic velocity (PSV), and end diastolic velocity (EDV) were evaluated at 30 days with duplex ultrasound. Results: A total of 103 patients underwent CAS procedure. Forty patients were symptomatic, and 63 patients were asymptomatic with stenosis greater than 70%. Technical success was 100%. Local anesthesia was applied in 94 patients (93%). Embolic protection devices were used in 6 patients (5.8%). Access site complications were 1.9%. Mean internal carotid artery stenosis diameter reduced from 79.47% to 14.68%. Two patients had transient ischemic attack (1.9%) and 1 patient experienced a cerebral hyperperfusion syndrome (CHS) perioperatively. External carotid artery (ECA) occlusion occurred in 1.9%. Four patients experienced jaw claudication (3.8%) postoperatively. Mean time of operation was 41 minutes. Mean duration of hospitalization was 3.1 days. The 30-day rate of MAE was 0%. CGuard patency was 100%, mean internal carotid PSV was reduced from 251.57 to 77.29 cm/s, and mean internal carotid EDV was reduced from 154.62 to 24.63 cm/s at 30 days. Conclusion: Our study shows that CGuard stent with EPS is an effective and safe device for treatment of carotid artery stenosis with acceptable low perioperative neurologic events, even with low embolic protection device usage. Larger multicenter and randomized studies are necessary to confirm its long-term efficacy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据