4.5 Article

High Sensitive Electrochemiluminescence Biosensor Based on Ru(phen)32+-loaded Double Strand DNA as Signal Tags use to Detect DNA Methyltransferase Activity

期刊

ELECTROANALYSIS
卷 34, 期 2, 页码 387-396

出版社

WILEY-V C H VERLAG GMBH
DOI: 10.1002/elan.202100184

关键词

Electrochemiluminescence biosensor; Dam MTase; Inhibitor; Hybridization chain reaction amplification; Methylation

资金

  1. National Sciences Foundation of China [21974020]
  2. Sciences Foundation of Fujian Province [2018J01685, 2018J01682]

向作者/读者索取更多资源

DNA methyltransferase can be a biomarker for many diseases. A highly efficient electrochemiluminescence sensor has been designed in this work for detection of DNA MTase. The sensor can specifically detect Dam MTase and has good applicability to detect its inhibitor with high efficiency.
DNA methyltransferase (DNA MTase) can act as biomarker for many diseases and it is important to develop some new methods for sensitive detection of DNA MTase. In this work, a highly efficient electrochemiluminescence (ECL) sensor had been designed for detection of DNA MTase based on Ru(phen)(3)(2+) loaded double strand DNA (dsDNA- Ru(phen)(3)(2+)) as signal tags. Ru(phen)(3)(2+) had been efficiently embed in the dsDNA produced through a simple hybridization chain reaction. First, a hairpin probe was designed, which can be specifically recognized by Dam MTase and modified with -SH at one end. It was modified on the surface of gold electrode by -SH as an immobilization probe (IP). This IP will be methylated in the present of Dam MTase and digested by DpnI following. Results in the release of capture probe (CP) which remains on the surface of gold electrode. The CP can hybridize with the single stand part of the dsDNA- Ru(phen)(3)(2+) and make the immobilization of ECL tags on the electrode surface, which results in a strong ECL signals detected. However, without the effect of Dam MTase, the hairpin structure of IP remains stable and cannot capture signal tags, and can only detecte weak ECL signals. The biosensor can detect the activity of Dam MTase in the concentration range of 0.01 U/mL to 20 U/mL with the ECL intensity and the logarithm of the concentration have a linear relationship, and the detection limit is calculated to be 7.6 mU/mL. The developed sensor has the ability to specifically detect Dam MTase, which can be differentiated from other types of DNA MTase. In addition, the designed method has good applicability to detect Dam MTase activity in serum samples and been applied to detect its inhibitor with high efficiency.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据