4.8 Article

Cell-based fluorescent microsphere incorporated with carbon dots as a sensitive immunosensor for the rapid detection of Escherichia coli O157 in milk

期刊

BIOSENSORS & BIOELECTRONICS
卷 179, 期 -, 页码 -

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2021.113057

关键词

Carbon dots; Fluorescent microspheres; Staphylococcal protein A; Staphylococcus aureus; Escherichia coli O157:H7

资金

  1. National Natural Science Foundation of China [81902160]
  2. Science and Technology Development Project of Jilin Province [20180201057YY]

向作者/读者索取更多资源

The study developed a highly sensitive fluorescent immunosensor using CDs-microspheres for the specific detection of Escherichia coli O157:H7 in milk, showing strong fluorescence intensity, good stability, and high uniformity in fluorescence. The immunosensor had a detection limit of 2.4 x 10(2) CFU/mL and could detect spiked E. coli O157:H7 in milk within 30 minutes with good repeatability. Additionally, the method could detect trace amounts of E. coli O157:H7 in real milk samples with 100% accuracy after bacterial enrichment, demonstrating its potential as a rapid and sensitive tool for pathogen detection in milk and other foods.
The rapid and early detection of foodborne pathogens in contaminated food is important for ensuring food safety and quality. In this study, a highly sensitive fluorescent immunosensor was developed to detect Escherichia coli O157:H7 in milk, by using microspheres labeled with carbon dots (CDs). The CDs-microspheres were prepared with Staphylococcus aureus cells as the carrier to incorporate CDs particles. Characterization of the microsphere revealed strong intensity, good stability and high uniformity in fluorescence. With Staphylococcal Protein A (SPA) on the surface of S. aureus cells, the microsphere could be easily coupled with various antibodies (e.g., immunoglobulin G). In combination with the immunomagnetic beads technique, a CDs-microsphere immunosensor was established for the specific detection of E. coli O157:H7 in milk. The limit of detection for E. coli O157: H7 is 2.4 x 10(2) colony-forming unit (CFU)/mL, comparable to that of real-time PCR methods. Milk samples spiked with E. coli O157:H7 at concentrations from 2.4 x 10(2) to 2.4 x 10(7) CFU/mL could be detected within 30 min. The coefficients of variation of the intra-assay tests were less than 10%, indicating a good repeatability. Moreover, the method was able to detect trace amounts of E. coli O157:H7 (<10 CFU) in real milk samples, with a 100% (10/10) accuracy after bacterial enrichment. This CDs-microsphere immunosensor shows considerable potential as a rapid and sensitive tool to detect pathogens in milk and other foods.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据