4.7 Article

Coupled electromagnetic-thermal analysis of roadway inductive power transfer pads within a model pavement

期刊

APPLIED THERMAL ENGINEERING
卷 189, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2021.116710

关键词

Inductive power transfer; Coupled multi-physics simulation; Pavement; FBG; Experimental test

资金

  1. New Zealand Ministry of Business, Innovation and Employment through MBIE Endeavour Fund [UOAX1711]
  2. New Zealand Ministry of Business, Innovation & Employment (MBIE) [UOAX1711] Funding Source: New Zealand Ministry of Business, Innovation & Employment (MBIE)

向作者/读者索取更多资源

The study focuses on thermal analysis of in-road wireless power transfer pads to address local temperature increases due to power losses. Through experimental validation, the proposed two-way coupled electromagnetic-thermal Finite Element simulation methods allow researchers to identify internal hotspots within road structures and develop reliable temperature measurement techniques.
Inductive Power Transfer (IPT) technology is a promising solution for wireless charging of Electric Vehicles (EVs). Given the expected uptake of IPT technology for both stationary and in motion in-road charging, many technical challenges regarding the electromagnetic field and thermal aspects need to be overcome to generate cost-effective and reliable solutions. One particular design constraint of in-road IPT systems is the occurrence of local increases in temperature during operation due to power losses in the wireless charging pads. In this paper, safe operating conditions of an enclosed wireless power transfer pad within a pavement model were identified. This aspect has been studied less rigorously compared with the electromagnetic design. This paper presents a numerical thermal analysis of a double-D (DD) prototype IPT primary pad based on two possible configurations; flush-mounted or buried, within a model pavement. A coupled electromagnetic-thermal simulation has been developed to aid in the development of thermally robust in-road IPT systems. In order to validate the proposed two-way coupled electromagnetic-thermal Finite Element (FE) simulations, experiments were performed to capture the evolving thermal field within an IPT primary pad under continuous and periodic duty cycles. This method made possible analysis of the heating patterns and so the identification of internal hotspots within an IPT pad in a roading structure. A thermal camera was used to provide detailed surface temperature distributions, while suitable application of non-metallic Fiber Bragg Grating (FBG) sensing technology enabled a robust technique to measure temperatures within the intense magnetic fields of a high frequency wireless power transfer system to be developed. Comparisons at steady state of the pavement surface temperature distribution, as well as point measurements with the pad and sand, demonstrate good accuracy. The maximum steady state surface temperature occurs at the centre of the sand surface where the IPT pad is placed and is approximately 87 degrees C and 100 degrees C for buried and flush-mounted pads, respectively. Moreover, for a 2/3 duty cycle loading, the maximum temperature of the pad tended to an average of approximately 76 degrees C, while at constant operation the average temperature is 105 degrees C. Therefore, a 5 min cooling period significantly reduced operating temperatures within the studied model IPT system. In the future, the methodologies proposed in this paper can also be used to improve the design of higher power IPT pads by identifying hotspots and maximum thermal stresses and determination of optimal charging patterns for heat dissipation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据