4.6 Article

Functionalization Strategies and Fabrication of Solvent-Cast PLLA for Bioresorbable Stents

期刊

APPLIED SCIENCES-BASEL
卷 11, 期 4, 页码 -

出版社

MDPI
DOI: 10.3390/app11041478

关键词

poly(l-lactic acid) solvent casting; surface modification; cold atmospheric plasma; cutinase enzyme; biocompatibility; 3D printed stent

资金

  1. Spanish Government [RTI2018-67183-R]
  2. Agency for Administration of University and Research Grants of the Government of Catalonia [2017SGR-1165]
  3. MINECO [PID2019-103892RB-I00]
  4. Erasmus Mundus Doctoral Programme DocMASE of the European Commission [FPA 2011 0020]
  5. European Union Regional Development Fund
  6. [BASE3D 001-P-001646]

向作者/读者索取更多资源

The study investigated the effect of different functionalization strategies on PLLA surfaces to enhance endothelial cell adhesion and the fabrication of 3D printed BRS. Surface functionalization with oxygen plasma, sodium hydroxide etching, or cutinase enzyme hydrolysis increased hydroxyl and carboxyl groups, improving endothelial cells adhesion without affecting degradation. 3D printed PLLA BRS stents were successfully produced using the solvent-cast direct writing technique.
Actual polymer bioresorbable stents (BRS) generate a risk of device thrombosis as a consequence of the incomplete endothelialization after stent implantation. The material-tissue interactions are not fully controlled and stent fabrication techniques do not allow personalized medical solutions. This work investigates the effect of different functionalization strategies onto solvent-cast poly(l-lactic acid) (PLLA) surfaces with the capacity to enhance surface endothelial adhesion and the fabrication of 3D printed BRS. PLLA films were obtained by solvent casting and treated thermally to increase mechanical properties. Surface functionalization was performed by oxygen plasma (OP), sodium hydroxide (SH) etching, or cutinase enzyme (ET) hydrolysis, generating hydroxyl and carboxyl groups. A higher amount of carboxyl and hydroxyl groups was determined on OP and ET compared to the SH surfaces, as determined by contact angle and X-ray photoelectron spectroscopy (XPS). Endothelial cells (ECs) adhesion and spreading was higher on OP and ET functionalized surfaces correlated with the increase of functional groups without affecting the degradation. To verify the feasibility of the approach proposed, 3D printed PLLA BRS stents were produced by the solvent-cast direct writing technique.