4.7 Article

Hotspot thermal management in microchannel heat sinks with vortex generators

期刊

出版社

ELSEVIER FRANCE-EDITIONS SCIENTIFIQUES MEDICALES ELSEVIER
DOI: 10.1016/j.ijthermalsci.2020.106727

关键词

Microchannel; Vortex generator; Hotspot; Heat transfer; Pressure drop

资金

  1. National Natural Science Foundation of China [51776117]

向作者/读者索取更多资源

This paper investigates hotspot-targeted thermal management using VGs in microchannels, showing that the adoption of VGs can significantly improve cooling effect over the hotspot with lower pressure loss.
Vortex generators (VGs) have been widely applied in the microchannel heat sinks to improve the thermal-hydraulic performance in multicore processors. However, most studies focus on global heat transfer enhancement of microchannel, while the hotspot temperature is often neglected. In this paper, a numerical study of hotspot-targeted thermal management using VGs is performed in a rectangular microchannel with a heat flux of 400 W/cm(2) and 50 W/cm(2) respectively at the hotspot and background region. With the maximum thermal resistance, pumping power and the overall performance factor as the key metrics, the performances of VGs in four configurations (co-flow-up, co-flow-down, counter-flow-up and counter-flow-down) are compared with a smooth microchannel without VG. Deionized water with temperature-dependent thermo-physical properties is used as the coolant with the Re in the range of 66-330. The results indicate that the adoption of VGs can significantly improve the cooling effect over the hotspot with a lower pressure loss penalty comparing with the smooth microchannel. In addition, the VGs in a co-flow configuration lead to the fluid circulation effect and transport the coolant in the core region of the microchannel to the sidewalls. It is also noted that comparing with the smooth microchannel, more than 78.8% pumping power can be saved by using the co-flow-down configuration to achieve the same cooling effect to maintain the average temperature at 304.7 K over the hotspot. Geometric parameter analysis reveals that the increase in the height and attack angle of VGs results in more pressure loss, whereas the enhanced heat transfer is insignificant when the VG's height ratio exceeds 0.2 or the attack angle surpasses 45 degrees. Taking full account of the heat transfer performance and pressure loss, VGs with a height ratio of 0.2 and attack angle of 45 degrees are recommended for practical applications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据