4.6 Article

On the synergistic effect of sulfonic functionalization and acidic adhesive conditioning to enhance the adhesion of PEEK to resin-matrix composites

期刊

DENTAL MATERIALS
卷 37, 期 4, 页码 741-754

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.dental.2021.01.017

关键词

Adhesion; PEEK; Etching; Universal adhesive; Resin composite; Shear bond strength

资金

  1. FCT-Portugal [UID/EEA/04436/2013]
  2. CNPq-Brazil [CNPq/UNIVERSAL/421229/2018-7]
  3. FCT-Portugal (LaserMULTICER) [POCI-01-0145-FEDER-031035]

向作者/读者索取更多资源

The combined effect of sulfuric acid etching and acidic adhesive conditioning significantly improved the shear bond strength of PEEK to a resin-matrix composite, demonstrating a synergistic effect between the two methods.
Objective. The objective of this study was to evaluate the combined effect of the sulfuric acid etching and an acidic adhesive conditioning on the shear bond strength of PEEK to a resin-matrix composite. Materials and methods. Forty PEEK specimens were assigned randomly to 4 groups for H2SO4 etching followed by universal adhesive (pH at 2.5) conditioning for 0, 1, 3, and 5 min. Thirty PEEK specimens were divided into 3 groups for only acidic adhesive conditioning for 0, 1, 3, and 5 min. After the light-curing of the adhesive, a nanohybrid resin composite was applied onto the surfaces and then light-cured following the manufacturer's guidelines. All specimens were stored in distilled water at 37 degrees C for 24 h mechanical testing. Shear bond strength tests were performed using a universal testing machine. Surfaces were analyzed by SEM, light interferometry, FTIR, and liquid contact angle measurement. Statistical analysis was performed by one-way ANOVA and Tukey's post hoc tests (p < 0.05). Results. No adhesion was achieved between untreated PEEK a resin-matrix composite, regardless of the adhesive conditioning time points. Shear bond strength of H2SO4-etched PEEK to resin-matrix composite increased with time (0 mmin. 4.95 +/- 2.86 MPa < 1 min: 9.35 +/- 2.26 MPa < 3 min: 17.84 +/- 2.82 MPa < 5 min: 21.43 +/- 5.00 MPa). SEM images revealed a significant modification of PEEK surface topography after the H2SO4 etching. Significance. The acidic adhesive was unable to modify the untreated PEEK surface to establish an effective adhesion although a synergistic effect was noticed when the universal (acidic) adhesive was applied over a H2SO4-etched PEEK surface, thus improving the PEEK to resin-matrix composite adhesion. (C) 2021 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据