4.5 Article

A Simple and Highly Stable Porous Gold-based Electrochemical Sensor for Bisphenol A Detection

期刊

ELECTROANALYSIS
卷 29, 期 2, 页码 472-480

出版社

WILEY-V C H VERLAG GMBH
DOI: 10.1002/elan.201600371

关键词

Porous Gold; Bisphenol A Detection; Reduce fouling effect; Electrochemical Sensor

资金

  1. Higher Education Research Promotion and National Research University Project of Thailand
  2. Office of the Higher Education Commission
  3. Center of Excellence for Innovation in Chemistry (PERCH-CIC) Office of the Higher Education Commission
  4. Trace Analysis and Biosensor Research Center
  5. and Graduate School, Prince of Songkla University, Hatyai, Thailand

向作者/读者索取更多资源

A porous gold electrode with a uniform pore size was prepared by a simple single potential step method. It provided around 19 times more surface area than a bare gold electrode. The porous gold electrode, without any modification, exhibited good electrocatalytic activity towards the oxidation of bisphenol A (BPA). The effect of the pH and scan rate, on the porous gold electrode was studied and discussed. Under optimum conditions of the flow system, the calibration plot of BPA was linear over a wide range of concentration, from 2.0nM to 800nM (R-2=0.999), and the detection limit was 2.0nM (s/n=3). It was of interest that, the porous gold electrode showed an exceptional result in minimizing the fouling from the oxidation product of BPA and led to a very high operational stability of the electrode for the detection of BPA (560 consecutive times). The porous gold electrode showed good fabrication reproducibility and can be used to detect bisphenol A that leached from baby bottles and drinking water bottles. The obtained results were in good agreement with the GC-MS method (P>0.05).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据