4.5 Article

Sample pooling of RNA extracts to speed up SARS-CoV-2 diagnosis using CDC FDA EUA RT-qPCR kit

期刊

VIRUS RESEARCH
卷 290, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.virusres.2020.198173

关键词

SARS-CoV-2; RT-qPCR; CDC; Pools

类别

向作者/读者索取更多资源

Background: The CDC protocol for SARS-CoV2 RT-PCR diagnosis (2019-nCoV CDC kit) is considered a gold standard worldwide; based on three different FAM probes (N1 and N2 for viral detection; RP for RNA extraction quality control), three reactions per sample are needed for SARS-CoV-2 diagnosis. Results: We herein describe a sample pooling protocol: pooling 3 RNA extractions into a single PCR reaction; we tested this protocol with 114 specimens grouped in 38 pools and found no significant differences for N1 and N2 Ct values between pool and single sample PCR reaction. Conclusion: This pool of three protocol has a sensitivity of 100 % compared to the standard single sample protocol. For a typical 96-well plate, this pool assay allows 96 samples processing, speeding up diagnosis and reducing cost while maintaining clinical performance, particularly useful for SARS-CoV-2 diagnosis at developing countries.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据