4.7 Article

Pilot trial of membrane distillation driven by low grade waste heat: Membrane fouling and energy assessment

期刊

DESALINATION
卷 391, 期 -, 页码 30-42

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.desal.2016.01.023

关键词

Membrane distillation; Industrial water treatment; Water reuse; Pilot trial; Waste heat

资金

  1. Victorian Smart Water Fund [72M-7078]
  2. Water Research Australia
  3. City West Water

向作者/读者索取更多资源

Direct contact membrane distillation (DCMD) supplied with waste heat was demonstrated for water recovery from saline demineralisation regeneration waste. The pilot plant was located at a gas fired power station which provided the <40 degrees C waste heat and wastewater to the DCMD system with 0.67 m(2) of membrane area. The trial was operated over three months without replacing the membranes or module and achieved 92.8% water recovery. Flux was approximately 3 L/(m(2).h) and was dependant mostly on the waste heat temperature being supplied. Membrane fouling affected flux and thermal energy demand only at the very end of the trial. The system produced a high quality distillate product with average 99.9% dissolved solids rejection. Small amounts of ammonia and carbon dioxide however were found in the permeate. Membrane analysis post-trial revealed fouling was principally inorganic scale but organic matter on the membrane was also evident. Permeate side fouling was also observed, attributed to corrosion of the cooling heat exchanger. Based on the available energy for a continuously operating 500 MW (electric) rated power station, the treatment potential was estimated at up to 8000 kL/day, which is practical for supplying water to numerous industrial, residential or agricultural sites. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据