4.7 Review

Diagnostic Performance of Noninvasive Imaging for Assessment of Axillary Response After Neoadjuvant Systemic Therapy in Clinically Node-positive Breast Cancer A Systematic Review and Meta-analysis

期刊

ANNALS OF SURGERY
卷 273, 期 4, 页码 694-700

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/SLA.0000000000004356

关键词

axillary response; breast cancer; imaging; neoadjuvant systemic therapy; node-positive

类别

资金

  1. Alpe d'Huzes Foundation (Dutch Cancer Society) [UM 2013-6229]
  2. Servier

向作者/读者索取更多资源

The diagnostic performance of current noninvasive imaging modalities is limited in accurately assessing axillary response after NST in clinically node-positive breast cancer patients. The overall axillary pathologic complete response rate was found to be 39.5%, with different imaging modalities showing varying levels of sensitivity, specificity, PPV, and NPV.
Objective: The purpose of this study was to perform a systematic review and meta-analysis to determine the diagnostic performance of current noninvasive imaging modalities for assessment of axillary response after neoadjuvant systemic therapy (NST) in clinically node-positive breast cancer patients. Summary of Background Data: NST can lead to downstaging of axillary lymph node disease. Imaging can potentially provide information about the axillary response to NST and, consequently, tailor the surgical management. Methods: PubMed and Embase were searched for studies that compared noninvasive imaging after NST with axillary surgery outcome to identify axillary response in patients with initial pathologically proven axillary lymph node metastasis. Two reviewers independently screened the studies and extracted the data. A meta-analysis was performed by computing the pooled sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Results: Thirteen studies describing 2380 patients were included for final analysis. Of these patients, 1322 had undergone axillary ultrasound, 849 breast MRI, and 209 whole-body F-18-FDG PET-CT. The overall axillary pathologic complete response rate was 39.5% (941/2380). For axillary ultrasound, the pooled sensitivity, specificity, PPV, and NPV were 65%, 69%, 77%, 50%, respectively. For breast MRI, the pooled sensitivity, specificity, PPV, and NPV were 60%, 76%, 78%, 58%, respectively. For whole-body F-18-FDG PET-CT, the pooled sensitivity, specificity, PPV, and NPV were 38%, 86%, 78%, 49%, respectively. Conclusions: The diagnostic performance of current noninvasive imaging modalities is limited to accurately assess axillary response after NST in clinically node-positive breast cancer patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据