Inhaler devices in asthma and COPD patients - a prospective cross-sectional study on inhaler preferences and error rates

期刊

BMC PULMONARY MEDICINE
卷 20, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12890-020-01246-z

关键词

Asthma; COPD; Device handling; Inhaler errors; Inhaler technique; Patient preference

资金

  1. Projekt DEAL

向作者/读者索取更多资源

Background Inhalation therapy is the backbone of asthma and COPD control. However, inhaler adherence and device mishandling continue to be a problem in real life. Some studies have shown that using a patient-preferred inhaler may reduce device handling errors and improve adherence to prescribed chronic inhaler drug therapy. The aim of this study was to compare the preferences for commonly used inhaler devices in Germany in patients with chronic obstructive respiratory disease. We also pursued the question which properties of an inhaler device are particularly important to the user and what effects age, gender and type of disease (asthma or COPD) may have on device preference and handling errors. Methods Prospective, open-label cross-sectional study in which 105 patients with asthma (58%) or COPD (42%) participated. Validated checklists were used to objectively assess inhaler technique and errors with 10 different placebo devices. For each device, patients were asked to test the handling, to assess the device properties and to name the device that they would most or least prefer. Results Across the 10 placebo inhaler devices tested, patients needed an average of 1.22 attempts to error-free use. The device with the lowest mean number of attempts was the Turbohaler (R) (1.02), followed by the Nexthaler (R) (1.04), the Diskus (R) (1.07) and the Spiromax (R) (1.10). Patients over 60 years vs. younger age (p = 0.002) and COPD vs. asthma patients (p = 0.016) required more attempts to ensure correct use. 41% of the study participants chose one of the devices they already used as the most preferred inhaler. Overall, 20% opted for the Spiromax (R), 15% for the Nexthaler (R) and 14% for the Turbohaler (R) or a pMDI. The least preferred device was the Elpenhaler (R) (0%). From a selection of 7 predefined inhaler attributes, patients stated easy handling as the most important for them. This was followed by short inhalation time and low inhalation resistance. Conclusions Patient preference may vary between inhaler devices. The lowest number of attempts to error-free use was reported for the Turbohaler (R) and the Nexthaler (R). The Spiromax (R) and the Nexthaler (R) achieved the best overall ratings and were the devices most preferred by patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据