4.6 Article

Time-optimal control of diafiltration processes in the presence of membrane fouling

期刊

COMPUTERS & CHEMICAL ENGINEERING
卷 91, 期 -, 页码 343-351

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.compchemeng.2016.04.018

关键词

Optimal control; Membrane fouling; Pontryagin's minimum principle; Diafiltration

资金

  1. Scientific Grant Agency of the Slovak Republic [1/0053/13]
  2. Slovak Research and Development Agency [APVV-0551-11]
  3. Slovak University of Technology in Bratislava
  4. STU Grant scheme for Support of Excellent Teams of Young Researchers
  5. Research 7 Development Operational Programme - ERDF

向作者/读者索取更多资源

This paper deals with time-optimal operation of batch diafiltration processes in the presence of membrane fouling. Fouling causes a decrease in the effective membrane area and, hence, an increase in processing time. In this work we study a time-optimal operation with several fouling models available in literature. Pontryagin's minimum principle is applied to characterize the structure of the optimal operation which voids any further on-line optimization. Due to the specific structure of the problem, it is possible, in several problem setups, to derive and verify an explicit analytic solution. Obtained results are applied in case studies where we provide a comparison between traditional operation and the proposed time-optimal operation. In cases, where the optimal operation cannot be identified analytically, we analyze the performance of sub-optimal control derived from neighboring analytical solution and compare it to optimal operation found via numerical optimization techniques. (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据