4.6 Article

Assessment of bridge natural frequency as an indicator of scour using centrifuge modelling

期刊

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s13349-020-00420-5

关键词

Vibration-based scour monitoring; Bridge scour; Natural frequency; Centrifuge modelling; Integral bridge

资金

  1. Cambridge Centre for Smart Infrastructure and Construction (Innovate UK) [920035]
  2. Cambridge Centre for Smart Infrastructure and Construction (EPSRC) [EP/N021614/1]
  3. Laing O'Rourke Centre for Construction Engineering and Technology
  4. Gates Cambridge Trust [OPP1144]
  5. EPSRC [EP/L010917/1] Funding Source: UKRI

向作者/读者索取更多资源

One of the most prevalent causes of bridge failure around the world is scour-the gradual erosion of soil around a bridge foundation due to fast-flowing water. A reliable technique for monitoring scour would help bridge engineers take timely countermeasures to safeguard against failure. Although vibration-based techniques for monitoring structural damage have had limited success, primarily due to insufficient sensitivity, these have tended to focus on the detection of local damage. High natural frequency sensitivity has recently been reported for scour damage. Previous experiments to investigate this have been limited as a result of the cost of full-scale testing and the fact that scaled-down soil-structure models tested outside a centrifuge do not adequately simulate full-scale behaviour. This paper describes the development of what is believed to be the first-ever centrifuge-testing programme to establish the sensitivity of bridge natural frequency to scour. A 1/60 scale model of a two-span integral bridge with 15 m spans was tested at varying levels of scour. For the fundamental mode of vibration, these tests found up to a 40% variation in natural frequency for 30% loss of embedment. Models of three other types of foundation, which represent a shallow pad foundation, a deep pile bent and a deep monopile, were also tested in the centrifuge at different scour levels. The shallow foundation model showed lower frequency sensitivity to scour than the deep foundation models. Another important finding is that the frequency sensitivity to global scour is slightly higher than the sensitivity to local scour, for all foundation types. The level of frequency sensitivity (3.1-44% per scour depth equivalent to 30% of embedment of scour) detected in this experiment demonstrates the potential for using natural frequency as an indicator of both local and global scour of bridges, particularly those with deep foundations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据