4.6 Article

A straightforward and semiautomated membrane-based method as efficient tool for the determination of cocaine and its metabolites in urine samples using liquid chromatography coupled to quadrupole time-of-flight-mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1621, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2020.461088

关键词

Cocaine; Urine; Microextraction; Sample preparation; High-throughput

资金

  1. Brazilian governmental agency Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)
  2. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES) [001]

向作者/读者索取更多资源

In this study, a novel and straightforward analytical methodology was proposed for the determination of cocaine (COC) and its main metabolites benzoylecgonine (BZE) cocaethylene (CE) and hydroxy-cocaine (COC-OH) in urine samples. This approach consisted of a high-throughput and semiautomated configuration based on hollow-fiber renewal liquid membrane extraction (HFRLM) coupled to a 96-well plate system, which was proposed for the first time to analyze complex biological samples such as urine. The analytical determinations were performed using ultra-high performance liquid chromatography coupled to quadrupole time-of-flight-mass spectrometry (LC-ESI-QTOF-MS). The analytical methodology was fully optimized through Doehlert and simplex-centroid designs, and univariate approaches. Polypropylene membranes of 1 cm length were inserted in the pins of an extraction blade combined with a 96-well plate system and its pores were filled with hexane:dichloromethane:ethyl acetate (1:1:1 v/v/v) for 180 s; moreover, 20 mu L of this mixture was added to the sample to allow for a renewable liquid membrane. The extraction step was carried out by keeping the blades immersed in vials containing 1.5 mL of diluted urine adjusted at pH 10 with 10% (w/v) of Na2CO3 during 20 min, followed by liquid desorption with 100 mu L of acetonitrile. Finally, the extract was dried under N-2 stream and resuspended with 20 of ultrapure water. Satisfactory analytical performance was obtained with coefficients of determination ranging from 0.9875 for BZE to 0.9986 for CE; intra-day precision ranged from 1.6 to 13.5%, and inter-day precision varied from 2.2 to 17.5%. Limits of detection ranged from 1.5 to 15.1 ng mL(-1), and limits of quantification varied from 5 to 50 ng mL(-1), with relative recoveries varied from 70.7 to 124.1%. (C) 2020 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据