4.3 Article

Application of digital volume correlation to study the efficacy of prophylactic vertebral augmentation

期刊

CLINICAL BIOMECHANICS
卷 39, 期 -, 页码 14-24

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.clinbiomech.2016.07.010

关键词

Prophylactic vertebral augmentation; Digital volume correlation; Cement-bone interface; Bone fracture; Micro-damage; Full-field three-dimensional strain measurement

资金

  1. Royal Society [RG130831]
  2. European Society of Biomechanics (ESB mobility award)

向作者/读者索取更多资源

Background: Prophylactic augmentation is meant to reinforce the vertebral body, but in some cases it is suspected to actually weaken it. Past studies only investigated structural failure and the surface strain distribution. To elucidate the failure mechanism of the augmented vertebra, more information is needed about the internal strain distribution. This study aims to measure, for the first time, the full-field three-dimensional strain distribution inside augmented vertebrae in the elastic regime and to failure. Methods: Eight porcine vertebrae were prophylactically-augmented using two augmentation materials. They were scanned with a micro-computed tomography scanner (38.8 mu m voxel resolution) while undeformed, and loaded at 5%, 10%, and 15% compressions. Internal strains (axial, antero-posterior and lateral-lateral components) Were computed using digital volume correlation. Findings: For both augmentation materials, the highest strains were measured in the regions adjacent to the injected cement mass, whereas the cement-interdigitated-bone was less strained. While this was already visible in the elastic regime (5%), it was a predictor of the localization of failure, which became visible at higher degrees of compression (10% and 15%), when failure propagated across the trabecular bone. Localization of high strains and failure was consistent between specimens, but different between the cement types. Interpretation: This study indicated the potential of digital volume correlation in measuring the internal strain (elastic regime) and failure in augmented vertebrae. While the cement-interdigitated region becomes stiffer (less strained), the adjacent non-augmented trabecular bone is affected by the stress concentration induced by the cement mass. This approach can help establish better criteria to improve vertebroplasty. (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据