4.3 Article

Fluorescence and Light Scatter Calibration Allow Comparisons of Small Particle Data in Standard Units across Different Flow Cytometry Platforms and Detector Settings

期刊

CYTOMETRY PART A
卷 97, 期 6, 页码 592-601

出版社

WILEY
DOI: 10.1002/cyto.a.24029

关键词

calibration; fluorescence; light scatter; EVs; reference materials; small particles; virus

资金

  1. Translational Nanobiology Section at the U.S. National Institutes of Health, National Cancer Institute [1ZIA-BC011502]
  2. University of Ottawa Faculty of Medicine
  3. Flow Cytometry and Virometry Core Facility
  4. NATIONAL CANCER INSTITUTE [ZIABC011942] Funding Source: NIH RePORTER
  5. NATIONAL CANCER INSTITUTE
  6. COMMON FUND, OFFICE OF THE DIRECTOR [ZIABC011502] Funding Source: NIH RePORTER

向作者/读者索取更多资源

Flow cytometers have been utilized for the analysis of submicron-sized particles since the late 1970s. Initially, virus analyses preceded extracellular vesicle (EV), which began in the 1990s. Despite decades of documented use, the lack of standardization in data reporting has resulted in a growing body of literature that cannot be easily interpreted, validated, or reproduced. This has made it difficult for objective assessments of both assays and instruments, in-turn leading to significant hindrances in scientific progress, specifically in the study of EVs, where the phenotypic analysis of these submicron-sized vesicles is becoming common-place in every biomedical field. Methods for fluorescence and light scatter standardization are well established and the reagents to perform these analyses are commercially available. However, fluorescence and light scatter calibration are not widely adopted by the small particle community as methods to standardize flow cytometry (FCM) data. In this proof-of-concept study carried out as a resource for use at the CYTO2019 workshop, we demonstrate for the first-time simultaneous fluorescence and light scatter calibration of small particle data to show the ease and feasibility of this method for standardized FCM data reporting. This data was acquired using standard configuration commercial flow cytometers, with commercially available materials, published methods, and freely available software tools. We show that application of light scatter, fluorescence, and concentration calibration can result in highly concordant data between FCM platforms independent of instrument collection angle, gain/voltage settings, and flow rate; thus, providing a means of cross comparison in standard units. (c) 2020 International Society for Advancement of Cytometry

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据