4.7 Article

Treprostinil Administered to Treat Pulmonary Arterial Hypertension Using a Fully Implantable Programmable Intravascular Delivery System Results of the DelIVery for PAH Trial

期刊

CHEST
卷 150, 期 1, 页码 27-34

出版社

ELSEVIER
DOI: 10.1016/j.chest.2015.11.005

关键词

central venous catheters; drugs; health-related quality of life; pulmonary arterial hypertension; pulmonary hypertension; treprostinil

资金

  1. Medtronic, Inc
  2. United Therapeutics Corporation

向作者/读者索取更多资源

BACKGROUND: The use of systemic prostanoids in severe pulmonary arterial hypertension (PAH) is often limited by patient/physician dissatisfaction with the delivery methods. Complications associated with external pump-delivered continuous therapy include IV catheter-related bloodstream infections and subcutaneous infusion site pain. We therefore investigated a fully implantable intravascular delivery system for treprostinil infusion. METHODS: A multicenter, prospective, single-arm, clinical trial (DelIVery for Pulmonary Arterial Hypertension) was conducted by using an implantable intravascular delivery system. The implanted pumps were refilled percutaneously at least every 12 weeks. The primary end point was the rate of catheter-related complications using the new model 10642 catheter compared with a predefined objective performance criterion of 2.5 per 1,000 patient-days based on the literature. RESULTS: Patients (n = 60) with severe PAH (World Health Organization group 1) receiving a stable dose of IV treprostinil for at least 4 weeks received an implant device and were followed up for 12.1 +/- 4.4 months. Six catheter-related complications occurred, corresponding to a complication rate of 0.27 per 1,000 patient-days. The 97.5% upper one-sided confidence bound of 0.59 was less than the predefined criterion of 2.5 per 1,000 patient-days (P < .0001). Plasma treprostinil levels at 1 week postimplantation were highly correlated with baseline levels (r = 0.91; P < .0001). The delivery system management time as reported by the patients was 2.5 +/- 1.7 hours per week preimplantation, and this time decreased to 0.6 +/- 0.8 hour per week at 6 months' postimplantation (P < .0001). All patients rated overall satisfaction with the implantable system as good, very good, or excellent at 6 weeks and 6 months. There were no catheter-related bloodstream infections or catheter occlusions. CONCLUSIONS: The implantable intravascular delivery system delivered treprostinil to patients with PAH with a low rate of catheter-related complications and a high rate of patient satisfaction.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据