4.7 Article

Selection of a phase change material and its thickness for application in walls of buildings for solar-assisted steam curing of precast concrete

期刊

RENEWABLE ENERGY
卷 150, 期 -, 页码 808-820

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.renene.2019.12.130

关键词

Prefabricated concrete (PC) components; Passive solar curing building; Phase change material (PCM) selection

资金

  1. National Key Research and Development Program of China, China [2016YFC0700206]
  2. Key Research and Development Program of Ningxia Autonomous Regio, China [2019BFF02005]

向作者/读者索取更多资源

Prefabricated concrete (PC) components require curing at the specific environment after being cast for the concrete to harden to the required levels over a certain period of time. Currently, steam curing is used as the major technique in concrete production. However, this method is highly energy consuming and requires large amounts of fossil fuels. Analysis of thermal process parameters in PC curing and thermal properties of phase change materials (PCMs), developed by the research team at Beijing University of Technology for the greenhouse applications, resulted in the development of the conceptual design of passive solar PC steam curing buildings with on-wall PCM heat storage. The process of selection of the PCM for installation on the inner surface of the main sun-facing wall of solar passive curing buildings is described. The selection is the result of the evaluation of suitable PCMs using the simultaneous process of transient energy consumption simulation with the deployment of EnergyPlus software and one-dimensional unsteady heat transfer modelling across the thickness of the thermal storage. The EnergyPlus simulations were calibrated against experimental data obtained in the curing building in Hebei Province, China. Theoretical simulations for such the building demonstrate that a GH-37 PCM panel with a thickness of 50 mm is suitable for such the application. The temperature range of phase transition for the GH-37 PCM is between 37.4 and 43.5 degrees C with latent heat equal to 227.5 kJ/kg. Compared to the same case but without PCM, the monthly and nocturnal average temperature of the inner surface of the main sun-facing wall increases by 1.3 degrees C and 2.7 degrees C, respectively. The heating load is reduced by 6.4, 5.8, 3.4 and 2.9 GJ in spring, autumn, summer and winter periods, respectively. The amount of annual steam consumption is reduced by 4.7%. (C) 2020 Elsevier Ltd. All rights reserved.Y

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据