IFCC Working Group Recommendations for Correction of Bias Caused by Noncommutability of a Certified Reference Material Used in the Calibration Hierarchy of an End-User Measurement Procedure
出版年份 2020 全文链接
标题
IFCC Working Group Recommendations for Correction of Bias Caused by Noncommutability of a Certified Reference Material Used in the Calibration Hierarchy of an End-User Measurement Procedure
作者
关键词
-
出版物
CLINICAL CHEMISTRY
Volume 66, Issue 6, Pages 769-778
出版商
Oxford University Press (OUP)
发表日期
2020-02-11
DOI
10.1093/clinchem/hvaa048
参考文献
相关参考文献
注意:仅列出部分参考文献,下载原文获取全部文献信息。- The role of external quality assessment in the verification of in vitro medical diagnostics in the traceability era
- (2018) Federica Braga et al. CLINICAL BIOCHEMISTRY
- Defining permissible limits for the combined uncertainty budget in the implementation of metrological traceability
- (2018) Federica Braga et al. CLINICAL BIOCHEMISTRY
- IFCC Working Group Recommendations for Assessing Commutability Part 2: Using the Difference in Bias between a Reference Material and Clinical Samples
- (2018) Göran Nilsson et al. CLINICAL CHEMISTRY
- IFCC Working Group Recommendations for Assessing Commutability Part 3: Using the Calibration Effectiveness of a Reference Material
- (2018) Jeffrey R. Budd et al. CLINICAL CHEMISTRY
- IFCC Working Group Recommendations for Assessing Commutability Part 1: General Experimental Design
- (2018) W. Greg Miller et al. CLINICAL CHEMISTRY
- Performance criteria for combined uncertainty budget in the implementation of metrological traceability
- (2015) Federica Braga et al. CLINICAL CHEMISTRY AND LABORATORY MEDICINE
- Defining analytical performance specifications: Consensus Statement from the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine
- (2015) Sverre Sandberg et al. CLINICAL CHEMISTRY AND LABORATORY MEDICINE
- Harmonization of growth hormone measurement results: The empirical approach
- (2014) H.A. Ross et al. CLINICA CHIMICA ACTA
- The Importance of Commutability of Reference Materials Used as Calibrators: The Example of Ceruloplasmin
- (2013) I. Zegers et al. CLINICAL CHEMISTRY
- Is the WHO 90:10 Prostate-Specific Antigen (PSA) First International Reference Standard Really 90% 1-Antichymotrypsin-Bound PSA and 10% Free PSA?
- (2011) L. J. Sokoll et al. CLINICAL CHEMISTRY
- Current parathyroid hormone immunoassays do not adequately meet the needs of patients with chronic kidney disease
- (2011) A. Almond et al. ANNALS OF CLINICAL BIOCHEMISTRY
- Report of the IFCC Working Group for Standardization of Thyroid Function Tests; Part 1: Thyroid-Stimulating Hormone
- (2010) L. M. Thienpont et al. CLINICAL CHEMISTRY
- Standardization of ceruloplasmin measurements is still an issue despite the availability of a common reference material
- (2009) Ilenia Infusino et al. ANALYTICAL AND BIOANALYTICAL CHEMISTRY
- Toward Standardization of Insulin Immunoassays
- (2009) W. G. Miller et al. CLINICAL CHEMISTRY
- Traceability in Laboratory Medicine
- (2009) H. W. Vesper et al. CLINICAL CHEMISTRY
Publish scientific posters with Peeref
Peeref publishes scientific posters from all research disciplines. Our Diamond Open Access policy means free access to content and no publication fees for authors.
Learn MoreCreate your own webinar
Interested in hosting your own webinar? Check the schedule and propose your idea to the Peeref Content Team.
Create Now