Continuous Flow Process for Cr(VI) Removal from Aqueous Solutions Using Resin Supported Zero-Valent Iron

期刊

出版社

SPRINGER
DOI: 10.1007/s00128-020-02843-8

关键词

nZVI nanocomposite; Macroreticular resin support; Chromate reduction; Continuous flow tests

向作者/读者索取更多资源

The study evaluated the performance of a nanocomposite material made of nano zero valent iron and a cation exchange resin for chromate reduction through column tests. The results showed that the removal of Cr(VI) follows a first order kinetic law.
The objective of the present study was to evaluate the performance of a nanocomposite material consisting of nano zero valent iron and a cation exchange resin, for the reduction of chromate, by conducting column tests. A cationic resin, Amberlyst 15, was selected as porous host material. The synthesis of the nanocomposite material (R-nFe) was carried out using Green Tea extract to obtain the reduction of adsorbed Fe(III) to the elemental state Fe(0). Three column tests were implemented with different dimensions, corresponding to variable contact times between the aqueous solution and the resin beads loaded with Fe(0), namely 168, 744 and 1260 s respectively for columns I, II and III. The results indicated that the removal of Cr(VI) follows a first order kinetic law with a chemical constant equal to 0.0526 min(-1)(8.8 x 10(-4) s(-1)).