期刊
APPLIED THERMAL ENGINEERING
卷 170, 期 -, 页码 -出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2020.114902
关键词
Triangular channel; Solar air heater; Differential form of mathematical modeling
In this study, a pilot plant of a triangular channel solar air heater with a U-turn airflow pattern was constructed and its performance was investigated using a developed model and experimental data under different operating conditions. A new equivalent radiation-convection circuit was developed as the most sophisticated part of the model. Based on the circuit, a mathematical model with minimal simplifying assumptions was developed to predict the performance of the heater. Compared with the results of an integral model of overall energy balance equations, the developed model showed a 50% reduction of error in prediction of thermal efficiency and outlet air temperature. The maximum thermal efficiency of the system could be obtained at an air mass flow rate of 0.045 kg/s (i.e. mass flux of 8.18 kg/m(2).s). Considering the air pressure drop (as the most important penalty) and outlet air temperature, the highest thermohydraulic performance was obtained at a channel internal peak angle of 60 degrees. Besides, the results indicated that to achieve a certain thermal efficiency, the presented solar air heater requires less surface area than that of a flat plate solar air heater for the same input solar radiation.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐