期刊
WATER RESEARCH
卷 167, 期 -, 页码 -出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.watres.2019.115111
关键词
Membrane cleaning; Physico-chemical cleaning; MnO2; H2O2
资金
- Fundamental Research Funds for the Central Universities [HIT. NSRIF. 2020028]
- Postdoctoral Science Foundation Grant, China [2018M641836]
The novel H2O2-MnO2 system was developed to achieve highly efficient membrane cleaning for both fouled PVDF and PES membranes in this study. Compared with conventional chemical cleaning process in which the whole membrane module had to be soaked in highly concentrated solution of chemical reagent for long period of time, the H2O2-MnO2 cleaning process conducting for only 5 min in 0.5 wt% H(2)O(2 )solution could achieve more than 95% recovery of permeate flux and almost total removal of the irreversible foulants. More importantly, the permeate flux and filtration efficiency of the membrane could be still kept stable after 6 runs of consecutive fouling and cleaning. Based on the systematic microscopic analyses, Electron Spin Resonance (ESR), Fourier Transform Infrared Spectroscopy (FTIR), as well as the quenching experiments with different free radical scavengers, the outstanding performance of H2O2-MnO2 system was attributed to the generation of both free radicals and abundant oxygen simultaneously, leading to the physico-chemical membrane cleaning. Conclusively, the newly developed H2O2-MnO2 system demonstrated noteworthy advantages on efficient membrane cleaning, and exhibited highly potential for the wide application in practical water treatment process. (C) 2019 Published by Elsevier Ltd.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐