4.4 Article

Rapid dealiasing of undersampled, non-Cartesian cardiac perfusion images using U-net

期刊

NMR IN BIOMEDICINE
卷 33, 期 5, 页码 -

出版社

WILEY
DOI: 10.1002/nbm.4239

关键词

cardiac perfusion; compressed sensing; deep learning; U-net

资金

  1. National Heart, Lung, and Blood Institute [R01HL116895, R01HL138578]
  2. National Institute of Biomedical Imaging and Bioengineering [R21EB024315]
  3. National Institute on Aging [R21AG055954]
  4. American Heart Association [19IPLOI34760317]
  5. National Institutes of Health [R01HL116895, R01HL138578, R21EB024315, R21AG055954]

向作者/读者索取更多资源

Compressed sensing (CS) is a promising method for accelerating cardiac perfusion MRI to achieve clinically acceptable image quality with high spatial resolution (1.6 x 1.6 x 8 mm(3)) and extensive myocardial coverage (6-8 slices per heartbeat). A major disadvantage of CS is its relatively lengthy processing time (8 min per slice with 64 frames using a graphics processing unit), thereby making it impractical for clinical translation. The purpose of this study was to implement and test whether an image reconstruction pipeline including a neural network is capable of reconstructing 6.4-fold accelerated, non-Cartesian (radial) cardiac perfusion k-space data at least 10 times faster than CS, without significant loss in image quality. We implemented a 3D (2D + time) U-Net and trained it with 132 2D + time datasets (coil combined, zero filled as input; CS reconstruction as reference) with 64 time frames from 28 patients (8448 2D images in total). For testing, we used 56 2D + time coil-combined, zero-filled datasets (3584 2D images in total) from 12 different patients as input to our trained U-Net, and compared the resulting images with CS reconstructed images using quantitative metrics of image quality and visual scores (conspicuity of wall enhancement, noise, artifacts; each score ranging from 1 (worst) to 5 (best), with 3 defined as clinically acceptable) evaluated by readers. Including pre- and post-processing steps, compared with CS, U-Net significantly reduced the reconstruction time by 14.4-fold (32.1 +/- 1.4 s for U-Net versus 461.3 +/- 16.9 s for CS, p < 0.001), while maintaining high data fidelity (structural similarity index = 0.914 +/- 0.023, normalized root mean square error = 1.7 +/- 0.3%, identical mean edge sharpness of 1.2 mm). The median visual summed score was not significantly different (p = 0.053) between CS (14; interquartile range (IQR) = 0.5) and U-Net (12; IQR = 0.5). This study shows that the proposed pipeline with a U-Net is capable of reconstructing 6.4-fold accelerated, non-Cartesian cardiac perfusion k-space data 14.4 times faster than CS, without significant loss in data fidelity or image quality.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据