4.4 Article

The role of viscoelastic damping on retrofitting seismic performance of asymmetric reinforced concrete structures

期刊

出版社

SPRINGER
DOI: 10.1007/s11803-020-0558-x

关键词

viscoelastic dampers; seismic analysis; asymmetric structure; nonlinear modal time history analysis

资金

  1. Ministry of Science and Technology of China [2017YFC0703603]
  2. National Natural Science Foundation of China [51678322]
  3. Taishan Scholar Priority Discipline Talent Group program - Shandong Province
  4. first-class discipline project - Education Department of Shandong Province

向作者/读者索取更多资源

The primary purpose of this research is to improve the seismic response of a complex asymmetric tall structure using viscoelastic (VE) dampers. Asymmetric structures have detrimental effects on the seismic performance because such structures create abrupt changes in the stiffness or strength that may lead to undesirable stress concentrations at weak locations. Structural control devices are one of the effective ways to reduce seismic impacts, particularly in asymmetric structures. For passive vibration control of structures, VE dampers are considered among the most preferred devices for energy dissipation. Therefore, in this research, VE dampers are implemented at strategic locations in a realistic case study structure to increase the level of distributed damping without occupying significant architectural space and reducing earthquake vibrations in terms of story displacements (drifts) and other design forces. It has been concluded that the seismic response of the considered structure retrofitted with supplemental VE dampers corresponded well in controlling the displacement demands. Moreover, it has been demonstrated that seismic response in terms of interstory drifts was effectively mitigated with supplemental damping when added up to a certain level. Exceeding the supplemental damping from this level did not contribute to additional mitigation of the seismic response of the considered structure. In addition, it was found that the supplemental damping increased the total acceleration of the considered structure at all floor levels, which indicates that for irregular tall structures of this type, VE dampers were only a good retrofitting measure for earthquake induced interstory deformations and their use may not be suitable for acceleration sensitive structures. Overall, the research findings demonstrate how seismic hazards to these types of structures can be reduced by introducing additional damping into the structure.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据