4.2 Article

Structure Optimization of Battery Module With a Parallel Multi-Channel Liquid Cooling Plate

出版社

ASME
DOI: 10.1115/1.4045197

关键词

lithium-ion battery; orthogonal test; structure optimization; battery thermal management; cooling plate

资金

  1. National Key R&D Program of China [2018YFB0104400]
  2. Natural Science Foundation of Jiangsu Province [BK20171300]

向作者/读者索取更多资源

In order to keep the power battery work within an ideal temperature range for the electric vehicle, the liquid cooling plate with parallel multi-channels is designed, and a three-dimensional thermal model of battery module with the liquid cooling plate is established. Subsequently, the effects of the cooling plate thickness and the cooling pipe thickness, channel number and coolant mass flow rate on the cooling performance of battery modules are analyzed. The results show that four parameters of the cooling plate have an important role in the thermal behavior of the liquid-cooled battery system. It is not good to improve the performance of the cooling system by changing only certain parameters. The four factors discussed above are optimized by using orthogonal test according to the univariate analysis. With the use of the orthogonal test, the optimization model obtained is obviously enhanced in the aspect of maximum temperature control and temperature uniformity of liquid-cooled battery module. Results show that the three-dimensional thermal analysis and orthogonal test method are compatible with optimal design of liquid-cooled battery modules.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据