4.8 Article

Graphene quantum dots FRET based sensor for early detection of heart attack in human

期刊

BIOSENSORS & BIOELECTRONICS
卷 79, 期 -, 页码 495-499

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2015.12.083

关键词

Graphene quantum dots; Cardiac Troponin I sensor; Myocardial infarction; FRET

资金

  1. Indian Council of Medical Research (ICMR), New Delhi

向作者/读者索取更多资源

Cardiac immunosensor for early detection of heart attack (myocardial infarction) was developed using amine functionalized graphene quantum dots (afGQDs) conjugated with antibody anti-cardiac Troponin I (anti-cTnI) to detect cardiac marker antigen Troponin I (cTnI) in blood based on fluorescence resonance energy transfer (FRET) between conjugate and graphene (quencher) only in 10 min. The anti-cTnI was covalently conjugated to afGQDs through carbodiimide coupling reaction. The conjugate was characterized by zeta potential UV-vis spectroscopy and field emission scanning electron microscopy (FES-EM). The sensing performance of the sensor was studied with respect to changes in the photon count and photoluminescence of GQDs based on interaction of target cTnI with its specific anti-cTnI antibody. The sensor is highly specific and shows negligible response to non-specific antigens. The sensor displayed a linear response to cTnI from 0.001 to 1000 ng mL(-1) with a limit of detection of 0.192 pg mL(-1). (C) 2015 Elsevier B.V. All rights reserved.