4.8 Article

pH-dependent ammonia removal pathways in microbial fuel cell system

期刊

BIORESOURCE TECHNOLOGY
卷 215, 期 -, 页码 290-295

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.biortech.2016.03.167

关键词

Microbial fuel cell; Ammonia removal; Ammonia recovery; Anammox; pH

资金

  1. Cooperative Research Program for Agriculture Science Technology Development (Project title: Development of resource recovery system based bioelectrochemical principle from livestock wastewater) of the Rural Development Administration, Republic of Korea [PJ0108242016]

向作者/读者索取更多资源

In this work, ammonia removal paths in microbial fuel cells (MFCs) under different initial pH conditions (pH 7.0, 8.0, and 8.6) were investigated. At a neutral pH condition (pH 7.0), MFC used an electrical energy of 27.4% and removed 23.3% of total ammonia by electrochemical pathway for 192 h. At the identical pH condition, 36.1% of the total ammonia was also removed by the biological path suspected to be biological ammonia oxidation process (e.g., Anammox). With the initial pH increased, the electrochemical removal efficiency decreased to less than 5.0%, while the biological removal efficiency highly increased to 61.8%. In this study, a neutral pH should be maintained in the anode to utilize MFCs for ammonia recovery via electrochemical pathways from wastewater stream. (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据