4.7 Article

Auto-calibration and real-time external parameter correction for stereo digital image correlation

期刊

OPTICS AND LASERS IN ENGINEERING
卷 121, 期 -, 页码 46-53

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.optlaseng.2019.03.018

关键词

Auto-calibration; Bundle adjustment; External parameter correction; Stereo digital image correlation

类别

资金

  1. National Natural Science Foundation of China (NSFC) [11532005, 11772092, 11827801, 61705060]

向作者/读者索取更多资源

Calibrating stereo digital image correlation (stereo-DIC) is crucial for 3D deformation measurements. Existing stereo-DIC calibration methods mainly rely on a well-made planar target with additional specific coding to perform pre-calibration. In this paper, a new method is proposed to calibrate a stereo-DIC system automatically with feature correspondences in an unconstrained scene. In contrast to traditional methods, the proposed method is scale-independent and does not require assumptions such as planarity. More importantly, it is capable of correcting disturbed external parameters in real time. With inverse depth parameterization, a stereo-DIC system can be effectively calibrated by a carefully designed bundle adjustment framework. Subsequently, a fast correction strategy based on massive-point subset tracking is derived to recalibrate the disturbed stereo-DIC system. The proposed method overcomes the predicament of reduced measurement accuracy due to the unavoidable disturbance of external parameters in dynamic deformation measurements. Experiments were conducted to verify the effectiveness of the proposed method.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据