4.7 Article

Universal atrial coordinates applied to visualisation, registration and construction of patient specific meshes

期刊

MEDICAL IMAGE ANALYSIS
卷 55, 期 -, 页码 65-75

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.media.2019.04.004

关键词

Mapping; Coordinates; Atria; Personalized computational modeling

资金

  1. Lefoulon-Delalande Foundation fellowship
  2. Medical Research Council Skills Development Fellowship [MR/S015086/1]
  3. French Government [ANR-10-IAHU-04]
  4. UK Engineering and Physical Sciences Research Council [EP/M012492/1, NS/A000049/1, EP/P01268X/1]
  5. British Heart Foundation [PG/15/91/31812, PG/13/37/30280]
  6. Kings Health Partners London National Institute for Health Research (NIHR) Biomedical Research Centre
  7. Wellcome/EPSRC Centre for Medical Engineering [WT 203148/Z/16/Z]
  8. Leducq Foundation [16 CVD 02]
  9. EPSRC [EP/P01268X/1, EP/M012492/1] Funding Source: UKRI
  10. MRC [MR/S015086/1] Funding Source: UKRI

向作者/读者索取更多资源

Integrating spatial information about atrial physiology and anatomy in a single patient from multimodal datasets, as well as generalizing these data across patients, requires a common coordinate system. In the atria, this is challenging due to the complexity and variability of the anatomy. We aimed to develop and validate a Universal Atrial Coordinate (UAC) system for the following applications: combination and assessment of multimodal data; comparison of spatial data across patients; 2D visualization; and construction of patient specific geometries to test mechanistic hypotheses. Left and right atrial LGE-MRI data were segmented and meshed. Two coordinates were calculated for each atrium by solving Laplace's equation, with boundary conditions assigned using five landmark points. The coordinate system was used to map spatial information between atrial meshes, including scalar fields measured using different mapping modalities, and atrial anatomic structures and fibre directions from a reference geometry. Average error in point transfer from a source mesh to a destination mesh and back again was less than 0.1 mm for the left atrium and 0.02 mm for the right atrium. Patient specific meshes were constructed using the coordinate system and phase singularity density maps from arrhythmia simulations were visualised in 2D. In conclusion, we have developed a universal atrial co-ordinate system allowing automatic registration of imaging and electroanatomic mapping data, 2D visualisation, and patient specific model creation. (C) 2019 The Authors. Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据